www.cisa.gov
Open in
urlscan Pro
2600:1408:c400:98c::447a
Public Scan
URL:
https://www.cisa.gov/news-events/ics-advisories/icsa-24-352-02
Submission: On December 18 via api from TR — Scanned from US
Submission: On December 18 via api from TR — Scanned from US
Form analysis
2 forms found in the DOM<form class="gsc-search-box gsc-search-box-tools" accept-charset="utf-8">
<table cellspacing="0" cellpadding="0" role="presentation" class="gsc-search-box">
<tbody>
<tr>
<td class="gsc-input">
<div class="gsc-input-box" id="gsc-iw-id1">
<table cellspacing="0" cellpadding="0" role="presentation" id="gs_id50" class="gstl_50 gsc-input" style="width: 100%; padding: 0px;">
<tbody>
<tr>
<td id="gs_tti50" class="gsib_a"><input autocomplete="off" type="text" size="10" class="gsc-input" name="search" title="search" aria-label="search" id="gsc-i-id1" dir="ltr" spellcheck="false"
style="width: 100%; padding: 0px; border: none; margin: 0px; height: auto; outline: none;"></td>
<td class="gsib_b">
<div class="gsst_b" id="gs_st50" dir="ltr"><a class="gsst_a" href="javascript:void(0)" title="Clear search box" role="button" style="display: none;"><span class="gscb_a" id="gs_cb50" aria-hidden="true">×</span></a></div>
</td>
</tr>
</tbody>
</table>
</div>
</td>
<td class="gsc-search-button"><button class="gsc-search-button gsc-search-button-v2"><svg width="13" height="13" viewBox="0 0 13 13">
<title>search</title>
<path
d="m4.8495 7.8226c0.82666 0 1.5262-0.29146 2.0985-0.87438 0.57232-0.58292 0.86378-1.2877 0.87438-2.1144 0.010599-0.82666-0.28086-1.5262-0.87438-2.0985-0.59352-0.57232-1.293-0.86378-2.0985-0.87438-0.8055-0.010599-1.5103 0.28086-2.1144 0.87438-0.60414 0.59352-0.8956 1.293-0.87438 2.0985 0.021197 0.8055 0.31266 1.5103 0.87438 2.1144 0.56172 0.60414 1.2665 0.8956 2.1144 0.87438zm4.4695 0.2115 3.681 3.6819-1.259 1.284-3.6817-3.7 0.0019784-0.69479-0.090043-0.098846c-0.87973 0.76087-1.92 1.1413-3.1207 1.1413-1.3553 0-2.5025-0.46363-3.4417-1.3909s-1.4088-2.0686-1.4088-3.4239c0-1.3553 0.4696-2.4966 1.4088-3.4239 0.9392-0.92727 2.0864-1.3969 3.4417-1.4088 1.3553-0.011889 2.4906 0.45771 3.406 1.4088 0.9154 0.95107 1.379 2.0924 1.3909 3.4239 0 1.2126-0.38043 2.2588-1.1413 3.1385l0.098834 0.090049z">
</path>
</svg></button></td>
<td class="gsc-clear-button">
<div class="gsc-clear-button" title="clear results"> </div>
</td>
</tr>
</tbody>
</table>
</form>
<form class="gsc-search-box gsc-search-box-tools" accept-charset="utf-8">
<table cellspacing="0" cellpadding="0" role="presentation" class="gsc-search-box">
<tbody>
<tr>
<td class="gsc-input">
<div class="gsc-input-box" id="gsc-iw-id2">
<table cellspacing="0" cellpadding="0" role="presentation" id="gs_id51" class="gstl_51 gsc-input" style="width: 100%; padding: 0px;">
<tbody>
<tr>
<td id="gs_tti51" class="gsib_a"><input autocomplete="off" type="text" size="10" class="gsc-input" name="search" title="search" aria-label="search" id="gsc-i-id2" dir="ltr" spellcheck="false"
style="width: 100%; padding: 0px; border: none; margin: 0px; height: auto; outline: none;"></td>
<td class="gsib_b">
<div class="gsst_b" id="gs_st51" dir="ltr"><a class="gsst_a" href="javascript:void(0)" title="Clear search box" role="button" style="display: none;"><span class="gscb_a" id="gs_cb51" aria-hidden="true">×</span></a></div>
</td>
</tr>
</tbody>
</table>
</div>
</td>
<td class="gsc-search-button"><button class="gsc-search-button gsc-search-button-v2"><svg width="13" height="13" viewBox="0 0 13 13">
<title>search</title>
<path
d="m4.8495 7.8226c0.82666 0 1.5262-0.29146 2.0985-0.87438 0.57232-0.58292 0.86378-1.2877 0.87438-2.1144 0.010599-0.82666-0.28086-1.5262-0.87438-2.0985-0.59352-0.57232-1.293-0.86378-2.0985-0.87438-0.8055-0.010599-1.5103 0.28086-2.1144 0.87438-0.60414 0.59352-0.8956 1.293-0.87438 2.0985 0.021197 0.8055 0.31266 1.5103 0.87438 2.1144 0.56172 0.60414 1.2665 0.8956 2.1144 0.87438zm4.4695 0.2115 3.681 3.6819-1.259 1.284-3.6817-3.7 0.0019784-0.69479-0.090043-0.098846c-0.87973 0.76087-1.92 1.1413-3.1207 1.1413-1.3553 0-2.5025-0.46363-3.4417-1.3909s-1.4088-2.0686-1.4088-3.4239c0-1.3553 0.4696-2.4966 1.4088-3.4239 0.9392-0.92727 2.0864-1.3969 3.4417-1.4088 1.3553-0.011889 2.4906 0.45771 3.406 1.4088 0.9154 0.95107 1.379 2.0924 1.3909 3.4239 0 1.2126-0.38043 2.2588-1.1413 3.1385l0.098834 0.090049z">
</path>
</svg></button></td>
<td class="gsc-clear-button">
<div class="gsc-clear-button" title="clear results"> </div>
</td>
</tr>
</tbody>
</table>
</form>
Text Content
Skip to main content An official website of the United States government Here’s how you know Here’s how you know Official websites use .gov A .gov website belongs to an official government organization in the United States. Secure .gov websites use HTTPS A lock (LockA locked padlock) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites. Free Cyber ServicesElection Threat Updates#protect2024Secure Our WorldShields UpReport A Cyber Issue Search × search Menu Close × search * Topics Topics Cybersecurity Best Practices Cyber Threats and Advisories Critical Infrastructure Security and Resilience Election Security Emergency Communications Industrial Control Systems Information and Communications Technology Supply Chain Security Partnerships and Collaboration Physical Security Risk Management How can we help? GovernmentEducational InstitutionsIndustryState, Local, Tribal, and TerritorialIndividuals and FamiliesSmall and Medium BusinessesFind Help LocallyFaith-Based CommunityExecutivesHigh-Risk Communities * Spotlight * Resources & Tools Resources & Tools All Resources & Tools Services Programs Resources Training Groups * News & Events News & Events News Events Cybersecurity Alerts & Advisories Directives Request a CISA Speaker Congressional Testimony CISA Conferences CISA Live! * Careers Careers Benefits & Perks HireVue Applicant Reasonable Accommodations Process Hiring Resume & Application Tips Students & Recent Graduates Veteran and Military Spouses Work @ CISA * About About Culture Divisions & Offices Regions Leadership Doing Business with CISA Site Links Reporting Employee and Contractor Misconduct CISA GitHub CISA Central 2024 Year In Review Contact Us Subscribe Free Cyber ServicesElection Threat Updates#protect2024Secure Our WorldShields UpReport A Cyber Issue Breadcrumb 1. Home 2. News & Events 3. Cybersecurity Advisories 4. ICS Advisory Share: ICS Advisory HITACHI ENERGY TROPOS DEVICES SERIES 1400/2400/6400 Release Date December 17, 2024 Alert Code ICSA-24-352-02 Related topics: Industrial Control System Vulnerabilities, Industrial Control Systems View CSAF(link is external) 1. EXECUTIVE SUMMARY * CVSS v3 5.3 * ATTENTION: Exploitable remotely/low attack complexity * Vendor: Hitachi Energy * Equipment: TropOS Devices Series 1400/2400/6400 * Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Hitachi Energy are affected: * TropOS devices series 1400/2400/6400: All versions prior to 8.9.6 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER INPUT VALIDATION CWE-20(LINK IS EXTERNAL) The monlist feature in ntp_request.c in ntpd in NTP before 4.2.7p26 allows remote attackers to cause a denial of service (traffic amplification) via forged (1) REQ_MON_GETLIST or (2) REQ_MON_GETLIST_1 requests, as exploited in the wild in December 2013. CVE-2013-5211(link is external) has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L(link is external)). 3.3 BACKGROUND * CRITICAL INFRASTRUCTURE SECTORS: Energy * COUNTRIES/AREAS DEPLOYED: Worldwide * COMPANY HEADQUARTERS LOCATION: Switzerland 3.4 RESEARCHER Hitachi Energy PSIRT reported this vulnerability to CISA. 4. MITIGATIONS Hitachi Energy has identified the following specific workarounds and mitigations users can apply to reduce risk: * Update to Version 8.9.6 or later when available * Hitachi Energy recommends users implement countermeasures for DoS with proper firewall rule sets and filters, as well as to apply mitigation as described in the Mitigation Factors/Workarounds Section. Hitachi Energy recommends users follow recommended security practices and firewall configurations, which can help protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system. For more information, see Hitachi Energy Cybersecurity Advisory "DoS Vulnerability in Hitachi Energy's TropOS core routers and edge nodes."(link is external) CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: * Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. * Locate control system networks and remote devices behind firewalls and isolating them from business networks. * When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. 5. UPDATE HISTORY * December 17, 2024: Initial Publication This product is provided subject to this Notification and this Privacy & Use policy. VENDOR * Hitachi Energy TAGS Sector: Energy Sector Topics: Industrial Control System Vulnerabilities, Industrial Control Systems PLEASE SHARE YOUR THOUGHTS We recently updated our anonymous product survey; we’d welcome your feedback. RELATED ADVISORIES Dec 17, 2024 ICS Advisory | ICSA-24-352-04 SCHNEIDER ELECTRIC MODICON Dec 17, 2024 ICS Advisory | ICSA-24-352-01 THREATQUOTIENT THREATQ PLATFORM Dec 17, 2024 ICS Advisory | ICSA-24-352-03 ROCKWELL AUTOMATION POWERMONITOR 1000 REMOTE Dec 12, 2024 ICS Advisory | ICSA-24-347-02 SIEMENS ENGINEERING PLATFORMS Return to top * Topics * Spotlight * Resources & Tools * News & Events * Careers * About Cybersecurity & Infrastructure Security Agency * Facebook * Twitter * LinkedIn * YouTube * Instagram * RSS CISA Central 1-844-Say-CISA SayCISA@cisa.dhs.gov DHS Seal CISA.gov An official website of the U.S. Department of Homeland Security * About CISA * Budget and Performance * DHS.gov * Equal Opportunity & Accessibility * FOIA Requests * No FEAR Act * Office of Inspector General * Privacy Policy * Subscribe * The White House * USA.gov * Website Feedback