www.thermofisher.com
Open in
urlscan Pro
104.104.86.194
Public Scan
Submitted URL: https://app.info7.thermofisher.com/e/er?CID=EM5104591_2_BIDXBUAWAREN_20240426%7C1452333&s=8285952&lid=11465&elqTrackId=d2fa61ccb0d6...
Effective URL: https://www.thermofisher.com/ca/en/home/life-science/cell-culture/transfection/neon-electroporation-system.html?CID=EM5104591...
Submission: On April 26 via manual from GB — Scanned from CA
Effective URL: https://www.thermofisher.com/ca/en/home/life-science/cell-culture/transfection/neon-electroporation-system.html?CID=EM5104591...
Submission: On April 26 via manual from GB — Scanned from CA
Form analysis
2 forms found in the DOMGET
<form id="smartsearch" method="get" autocomplete="off" class="providers-enabled"><select id="chosenselector" class="searchAutoCompleteProviderSelector" style="display: none;">
<option value="all-categories">Search All</option>
<option value="trial-catalog">Aspire Free Products</option>
<optgroup label="Popular Product Areas">
<option value="taqman-assays">TaqMan Assays</option>
<option value="primary-antibodies">Primary Antibodies</option>
<option value="secondary-antibodies">Secondary Antibodies</option>
<option value="elisa-kits">ELISA Kits</option>
</optgroup>
<option value="all-documents-support">All Documents & Support</option>
<option value="certificates">Certificates</option>
<option value="sds">SDS</option>
<option value="manuals-and-protocols">Manuals & Protocols</option>
<option value="product-faqs">Product FAQs</option>
</select>
<input type="hidden" value="1" name="resultPage">
<input type="hidden" value="15" name="resultsPerPage">
<div class="general_search layout_cont_left">
</div>
<div class="general_search layout_cont_right">
<button id="searchButton" type="submit" class="search-button" formaction="/search/results" tabindex="-1">
<p class="search-text">Search</p>
<svg class="search-btn-icon" role="img" version="1.1" xmlns="http://www.w3.org/2000/svg" xmlns:xlink="http://www.w3.org/1999/xlink" xml:space="preserve">
<defs>
<style>
.cls-1-white {
fill: #FFFFFF;
}
</style>
</defs>
<title>Search button</title>
<g id="Layer_462" data-name="Layer 462">
<path class="cls-1-white" d="M27.49,26.45l-6.34-6.34a9.71,9.71,0,0,0-.31-13.42,9.76,9.76,0,0,0-13.77,0A9.73,9.73,0,0,0,19.66,21.45l6.41,6.42ZM8.48,19A7.73,7.73,0,1,1,14,21.31,7.68,7.68,0,0,1,8.48,19Z"></path>
</g>
</svg>
</button>
</div>
<div class="general_search layout_cont_middle">
<div id="generalSearchInput">
<div id="header-typeahead-input-container">
<input class="data-hj-whitelist" id="suggest1" name="query" accesskey="s" value="" role="search" autocomplete="off" placeholder="Search by catalog number, product name, keyword, application" tabindex="0">
<input id="header-typeahead-suggested" autocomplete="off">
</div>
<i id="searchMagnifyMobile" class="searchMagnifyMobile">
<svg class="search-btn-icon" role="img" version="1.1" xmlns="http://www.w3.org/2000/svg" xmlns:xlink="http://www.w3.org/1999/xlink" xml:space="preserve"><defs><style>.cls-1-grey{fill:#70707A;}</style></defs><title>Search button</title><g id="Layer_462" data-name="Layer 462"><path class="cls-1-grey" d="M27.49,26.45l-6.34-6.34a9.71,9.71,0,0,0-.31-13.42,9.76,9.76,0,0,0-13.77,0A9.73,9.73,0,0,0,19.66,21.45l6.41,6.42ZM8.48,19A7.73,7.73,0,1,1,14,21.31,7.68,7.68,0,0,1,8.48,19Z"></path></g></svg>
</i>
<i id="searchRemove" class="clearable searchRemoveHide">
<svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 28 18"><defs><style>.cls-1-grey{fill:#54545C;}</style></defs><title>Close</title><g id="Layer_154" data-name="Layer 154"><path class="cls-1-grey" d="M9.40199 0L0.148438 8.82L9.40199 17.64H27.8147V0H9.40199ZM25.7164 15.64H10.2623L3.10706 8.82L10.2623 2H25.7164V15.64ZM12.0773 12.09L15.5081 8.82L12.0773 5.63L13.5567 4.22L16.9454 7.45L20.3342 4.22L21.824 5.63L18.4772 8.82L21.866 12.05L20.3762 13.47L16.9874 10.24L13.5986 13.47L12.0773 12.09Z"></path></g></svg>
</i>
<div id="header-typeahead" style="display: none;">
<input type="hidden" id="typeahead-autocomplete" name="autocomplete">
<div>
<ul class="flyout-recent-searches hide"></ul>
</div>
<div class="flyout-typeahead">
<div class="typeahead-terms">
<ul class="typeahead-term-list"></ul>
</div>
<div class="flyout-search-shortcut_right">
<ul class="search-shortcut-list"></ul>
</div>
</div>
<div class="flyout-search-shortcut">
<ul class="search-shortcut-list"></ul>
</div>
</div>
</div>
</div>
</form>
Name: productForm_afaaf07c-2c16-4976-8683-b6c27b5deb85MainParsysproductlist_316d — POST
<form method="post" name="productForm_afaaf07c-2c16-4976-8683-b6c27b5deb85MainParsysproductlist_316d" id="productForm_afaaf07c-2c16-4976-8683-b6c27b5deb85MainParsysproductlist_316d">
<div class="scrollable-table-container">
<div class="scrollable-table">
<table class="productlist-mobile-collapse table-mobile-collapse table table-bordered table-list table-striped">
<thead>
<tr>
<th class="table-list-sku">Catalog #</th>
<th class="table-list-name">Name</th>
<th class="table-list-size">Size</th>
<th class="table-list-price">Price (CAD)</th>
<th class="table-list-qty">Qty</th>
<th class="table-qty-placeholder"></th>
</tr>
</thead>
<tbody>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/NEON1S">NEON1S</a></td>
<td data-title="Name"><a href="/order/catalog/product/NEON1S">Neon™ NxT Electroporation System</a></td>
<td data-title="Size">Each </td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">13,770.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty1" id="qty1"><input type="hidden" name="sku" value="NEON1S">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System">
<input type="hidden" name="size" value="Each ">
<input type="hidden" name="price" value="13,770.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/NEON1SK">NEON1SK</a></td>
<td data-title="Name"><a href="/order/catalog/product/NEON1SK">Neon™ NxT Electroporation System Starter Pack</a></td>
<td data-title="Size">Each </td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">18,180.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty2" id="qty2"><input type="hidden" name="sku" value="NEON1SK">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System Starter Pack">
<input type="hidden" name="size" value="Each ">
<input type="hidden" name="price" value="18,180.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/N1025">N1025</a></td>
<td data-title="Name"><a href="/order/catalog/product/N1025">Neon™ NxT Electroporation System 10-μL Kit</a></td>
<td data-title="Size">25 x 2 reactions</td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">1,006.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty3" id="qty3"><input type="hidden" name="sku" value="N1025">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System 10-μL Kit">
<input type="hidden" name="size" value="25 x 2 reactions">
<input type="hidden" name="price" value="1,006.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/N10025">N10025</a></td>
<td data-title="Name"><a href="/order/catalog/product/N10025">Neon™ NxT Electroporation System 100-μL Kit</a></td>
<td data-title="Size">25 x 2 reactions</td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">1,012.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty4" id="qty4"><input type="hidden" name="sku" value="N10025">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System 100-μL Kit">
<input type="hidden" name="size" value="25 x 2 reactions">
<input type="hidden" name="price" value="1,012.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/N1096">N1096</a></td>
<td data-title="Name"><a href="/order/catalog/product/N1096">Neon™ NxT Electroporation System 10-μL Kit</a></td>
<td data-title="Size">96 x 2 reactions</td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">2,970.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty5" id="qty5"><input type="hidden" name="sku" value="N1096">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System 10-μL Kit">
<input type="hidden" name="size" value="96 x 2 reactions">
<input type="hidden" name="price" value="2,970.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/N10096">N10096</a></td>
<td data-title="Name"><a href="/order/catalog/product/N10096">Neon™ NxT Electroporation System 100-μL Kit</a></td>
<td data-title="Size">96 x 2 reactions</td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">2,975.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty6" id="qty6"><input type="hidden" name="sku" value="N10096">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System 100-μL Kit">
<input type="hidden" name="size" value="96 x 2 reactions">
<input type="hidden" name="price" value="2,975.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/NT96">NT96</a></td>
<td data-title="Name"><a href="/order/catalog/product/NT96">Neon™ NxT Electroporation System Tubes</a></td>
<td data-title="Size">96 tubes</td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">856.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty7" id="qty7"><input type="hidden" name="sku" value="NT96">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System Tubes">
<input type="hidden" name="size" value="96 tubes">
<input type="hidden" name="price" value="856.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/NEON1P">NEON1P</a></td>
<td data-title="Name"><a href="/order/catalog/product/NEON1P">Neon™ NxT Electroporation System Pipette</a></td>
<td data-title="Size">1 pipette</td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">1,146.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty8" id="qty8"><input type="hidden" name="sku" value="NEON1P">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System Pipette">
<input type="hidden" name="size" value="1 pipette">
<input type="hidden" name="price" value="1,146.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
<tr>
<td data-title="Catalog #"><a href="/order/catalog/product/NEON1PS">NEON1PS</a></td>
<td data-title="Name"><a href="/order/catalog/product/NEON1PS">Neon™ NxT Electroporation System Pipette Station</a></td>
<td data-title="Size">1 station</td>
<td data-title="Price (CAD)">
<div class="price-group price-add-to-cart" data-add-to-cart-mode="1">
<div class="price price-list">
<span class="price-amount">1,660.00</span>
</div>
</div>
</td>
<td data-title="Qty">
<input type="text" maxlength="3" class="input span1" name="qty9" id="qty9"><input type="hidden" name="sku" value="NEON1PS">
<input type="hidden" name="productname" value="Neon™ NxT Electroporation System Pipette Station">
<input type="hidden" name="size" value="1 station">
<input type="hidden" name="price" value="1,660.00">
<input type="hidden" name="assayID">
<input type="hidden" name="assayName">
<input type="hidden" name="purity">
<input type="hidden" name="scale">
</td>
<td class="table-mobile-addcart">
<input class="btn btn-success btn-block-stacked btn-mobile-prodlistadd" value="Add to cart" type="button">
</td>
</tr>
</tbody>
<tfoot>
<tr>
<td colspan="6">
<input id="addToCart_afaaf07c-2c16-4976-8683-b6c27b5deb85MainParsysproductlist_316d" onclick="productListCartHandler.addToCart('productForm_afaaf07c-2c16-4976-8683-b6c27b5deb85MainParsysproductlist_316d')"
class="btn-block-stacked btn btn-success pull-right" value="Add to cart" type="button">
</td>
</tr>
</tfoot>
</table>
</div>
</div>
</form>
Text Content
Skip to main content Enable accessibility for visually impaired Open the accessibility menu Open the Accessible Navigation Menu Hamburger Menu Button Thermo Fisher Scientific Logo Sign in Don't have an account ? Create Account * Products * Antibodies * Cell Culture Media * Chemicals * Chromatography Columns and Cartridges * Lab Equipment * Lab Plasticware and Supplies * Microplates * Oligos, Primers, Probes and Genes * TaqMan Real-Time PCR Assays * Greener Products * See all product categories * Applications * Bioprocessing * Cell Culture and Transfection * Cell and Gene Therapy * Chromatography * Molecular Testing * Digital Solutions * DNA and RNA Extraction and Analysis * Spectroscopy, Elemental and Isotope Analysis * See all applications and techniques * Services * CDMO and Clinical Trial Services * Custom Services * Enterprise Services * Financial and Leasing Services * Instrument Services * Lab Informatics * OEM and Commercial Supply * Training Services * Unity Lab Services * See all services * Help and Support * How to Order * Instrument Support * Learning Centers * Register for an Account * Technical Support Centers * See all help and support topics * Popular * TaqMan Real-Time PCR Assays * Antibodies * Oligos, Primers & Probes * GeneArt Gene Synthesis * Cell Culture Plastics * Contact Us * Quick Order * Order Status and Tracking * Documents and Certificates Thermo Fisher Scientific Logo Search Thermo Fisher Scientific Search All Search AllAspire Free ProductsTaqMan AssaysPrimary AntibodiesSecondary AntibodiesELISA KitsAll Documents & SupportCertificatesSDSManuals & ProtocolsProduct FAQs Search Search button Search button Close * Order Status * Quick Order * Sign in Sign in Don't have an account ? Create Account * * * Account * Aspire Member Program * Connect: Lab, Data, Apps * Check Order Status * Custom Products & Projects * Instrument Management * * Home› * Life Sciences› * Cell Culture & Transfection› * Cell Transfection: High Efficiency Solutions› * Neon NxT Electroporation System NEON NXT ELECTROPORATION SYSTEM: TRUSTED TRANSFECTION PERFORMANCE Request Demo/Quote Protocol library See Navigation ‹Cell Transfection: High Efficiency Solutions * Transfection Reagents › * Neon NxT Electroporation System › * Transfection Applications › * Overview of Transfection Methods › * Transfection Resources › Protect your valuable research time and samples with a compact electroporation machine designed and engineered for performance, speed, simplicity, and flexibility. The combination of the Invitrogen Neon NxT Electroporation System’s proprietary pipette tip technology, simplified workflow, and flexibility helps reduce sample loss, lowers contamination risk, saves you steps, and can put you in control of your experiments. BENEFITS OF THE NEON NXT ELECTROPORATION SYSTEM * Proven transfection efficiency and cell viability—transfect challenging cell lines with high efficiency and high cell viability * Flexibility when you need it—precisely optimize electroporation parameters for different cell types, cell densities, payloads, and electroporation protocols. * Enhanced genome editing efficiency—optimized buffer for improved delivery of CRISPR molecules * Save valuable research time—transfect cells quickly with an easy three step workflow, a single buffer kit and intuitive user interface * Preserve your precious samples—minimize sample transfer loss and contamination risk Download brochure Invitrogen TransfectionLab, a cloud-based app can automatically generate step-by-step guide tailored for each electroporation experiment, starting from the design stage. You can remotely set up multiple plate layouts for up to 384 samples, and any protocol or plate layout saved in the app can be accessed directly on the connected Neon NxT system. ORDER THE NEON NXT ELECTROPORATION SYSTEM neon1s,neon1sk,n1025,n10025,n1096,n10096,nt96,neon1p,neon1ps Catalog # Name Size Price (CAD) Qty NEON1S Neon™ NxT Electroporation System Each 13,770.00 NEON1SK Neon™ NxT Electroporation System Starter Pack Each 18,180.00 N1025 Neon™ NxT Electroporation System 10-μL Kit 25 x 2 reactions 1,006.00 N10025 Neon™ NxT Electroporation System 100-μL Kit 25 x 2 reactions 1,012.00 N1096 Neon™ NxT Electroporation System 10-μL Kit 96 x 2 reactions 2,970.00 N10096 Neon™ NxT Electroporation System 100-μL Kit 96 x 2 reactions 2,975.00 NT96 Neon™ NxT Electroporation System Tubes 96 tubes 856.00 NEON1P Neon™ NxT Electroporation System Pipette 1 pipette 1,146.00 NEON1PS Neon™ NxT Electroporation System Pipette Station 1 station 1,660.00 NEON1S,NEON1SK,N1025,N10025,N1096,N10096,NT96,NEON1P,NEON1PS HOW TO USE THE NEON NXT ELECTROPORATION SYSTEM CUSTOMER STORY Video Player is loading. Play Video PlaySkip Backward Mute Current Time 0:00 / Duration 2:05 Loaded: 7.93% 0:00 Stream Type LIVE Seek to live, currently behind liveLIVE Remaining Time -2:05 Share 1x Playback Rate Chapters * Chapters Descriptions * descriptions off, selected Captions * captions settings, opens captions settings dialog * captions off, selected Audio Track * en (Main), selected Picture-in-PictureFullscreen This is a modal window. Beginning of dialog window. Escape will cancel and close the window. TextColorWhiteBlackRedGreenBlueYellowMagentaCyanOpacityOpaqueSemi-TransparentText BackgroundColorBlackWhiteRedGreenBlueYellowMagentaCyanOpacityOpaqueSemi-TransparentTransparentCaption Area BackgroundColorBlackWhiteRedGreenBlueYellowMagentaCyanOpacityTransparentSemi-TransparentOpaque Font Size50%75%100%125%150%175%200%300%400%Text Edge StyleNoneRaisedDepressedUniformDropshadowFont FamilyProportional Sans-SerifMonospace Sans-SerifProportional SerifMonospace SerifCasualScriptSmall Caps Reset restore all settings to the default valuesDone Close Modal Dialog End of dialog window. Close Modal Dialog This is a modal window. This modal can be closed by pressing the Escape key or activating the close button. Close Modal Dialog This is a modal window. This modal can be closed by pressing the Escape key or activating the close button. Neon NxT University Lab Partners Testimonial Video In this video, Samantha Renusch, the Education Program Manager at University Lab Partners, shares her experience using the Neon NxT Electroporation System. ACHIEVE HIGH TRANSFECTION EFFICIENCY AND HIGH CELL VIABILITY IN A BROAD RANGE OF CELL LINES USING THIS TRANSFECTION SYSTEM The Neon NxT Electroporation System is an electroporation instrument that offers up to 90% transfection and gene-editing efficiency in extremely difficult-to-transfect cells, including immune, primary, and stem cells. Over 150 cell lines have been tested with optimized ready-to-use conditions for efficiency and viability. Search the Transfection protocols and citations database for optimized electroporation protocols on different cell lines. Figure 1. Transfection efficiency with the Neon NxT Electroporation System. Cells were transfected with GFP plasmid DNA or GFP mRNA in 10 μL or 100 μL electroporation reactions. Transfection efficiency is reported as the percentage of GFP-positive cells (n = 3). Note: Naive T cells were only electroporated in 100 μL reactions. -------------------------------------------------------------------------------- Figure 2. Cell viability following electroporation on the Neon NxT system. Cells were transfected with GFP plasmid DNA or GFP mRNA in 10 μL or 100 μL electroporation reactions. Transfected cells were stained with Invitrogen SYTO Red Dead Cell Stain and assessed for viability on the Invitrogen ATTUNE NxT Flow Cytometer. Cell viability (%) is reported as the mean of 3 measurements. Note: Naive T cells were only electroporated in 100 μL reactions. -------------------------------------------------------------------------------- Figure 3. Performance of Neon NxT Resuspension Genome Editing Buffer in CRISPR-Cas9–based genome editing experiments. Cells were electroporated in 10 μL or 100 μL reactions. (A) GFP donor DNA knock-in efficiency reported as the percentage of GFP-positive cells. (B) Viability of cells after GFP donor DNA knock-in. (C) Knockout efficiency reported as percentage of initial GFP-positive cells not expressing GFP after electroporation. (D) Post-electroporation viability of knockout cells. ENHANCING GENOME EDITING EFFICIENCY Genome editing holds great promise in the pursuit of a greater understanding of human health and disease. A critical, yet challenging step in the genome editing workflow is the effective delivery of CRISPR ribonucleoprotein (RNP), DNA and RNA molecules into the cell line of choice—also known as transfection. As demonstrated above, electroporation is the most widely used delivery method for its ability to achieve high transfection efficiency, even with hard-to-transfect cells. When used with the Neon NxT Electroporation System, our gene editing reagents and the Neon NxT Resuspension Genome Editing Buffer can help improve gene editing performance with specific payloads like CRISPR Cas9 for knockout or knock-in experiments with mammalian cells including primary, stem, and difficult-to-transfect cells (Figure 3). Explore our comprehensive suite of gene editing workflow solutions at thermofisher.com/geneediting WHY IS THE NEON NXT ELECTROPORATION SYSTEM A BETTER ALTERNATIVE TO THE ELECTROPORATION CUVETTE? Figure 4. Neon NxT pipette tip advantages compared to standard electroporation cuvette. The proprietary biologically compatible (A) Neon NxT tip presents a proven capillary electroporation technology that has important advantages over (B) electroporation cuvettes. Unlike standard cuvette-based electroporation chambers, the Neon NxT electroporation system uses a proprietary biologically compatible pipette tip chamber that generates a more uniform electric field. This design allows for a better maintenance of physiological conditions resulting in high cell survival compared to conventional electroporation.† * Creates a more uniform electric field * Maintains a stable pH throughout the electroporation chamber * Generates minimal heat * Forms fewer ions * Reduces shear force experienced by cells PRECISELY OPTIMIZE ELECTROPORATION PARAMETERS FOR DIFFERENT CELL TYPES, CELL DENSITIES, PAYLOADS, AND ELECTROPORATION PROTOCOLS CUSTOMIZABLE ELECTROPORATION PARAMETERS With the Neon NxT Electroporation System, you can precisely control the parameters that matter most for your experiment without wasting precious time adjusting those that do not. This transfection system allows you to modify: * Pulse voltage * Pulse width * Number of pulses * Cell type * Buffer type * Payload type VERSATILITY FOR DIFFERENT PAYLOADS, CELL TYPES, AND CELL DENSITIES Deliver DNA, RNA, or protein to a wide variety of mammalian cells, with the flexibility to transfect 1 x 104 to 1 x 107 cells per reaction. TRANSFECT CELLS QUICKLY WITH AN EASY THREE-STEP WORKFLOW, A SINGLE BUFFER KIT, AND AN INTUITIVE USER INTERFACE SIMPLIFIED ELECTROPORATION WORKFLOW Easy to follow and execute, the Neon NxT Electroporation System streamlined workflow requires minimal training and improves consistency and reproducibility. Using this transfection system, the electroporation process is simple: first, take up cells and plasmid mix into the Neon NxT pipette tip. Second, plug into the pipette holder, and press Electroporate. Finally, pipette the transfected cells back into your culture vessel. As the transfection occurs in the pipette tip, the transfection is completed in just 3 simple steps: Aspirate, Electroporate, Dispense. Step 1 ASPIRATE Prepare cells by suspending them in a Neon NxT buffer. Load cells and payload mix suspended in Neon NxT buffer into the Neon NxT pipette tip.Step 2 ELECTROPORATE Apply electrical pulses to cells to deliver the payload in the specialized buffer.Step 3 DISPENSE Restore growth conditions to allow the transfected cells to recover.Step 4 ANALYZE CELLS Evaluate: e.g., gene expression, genome editing, silencing, and cell line development SHORTER PROCESSING TIME USING THIS ELECTROPORATION SYSTEM In addition to simplifying the workflow, our proprietary electroporation technology shortens the overall process to 10–15 minutes, compared to a conventional electroporation system as the transfection occurs in the Neon NxT pipette tip.† A SINGLE BUFFER KIT FOR MANY MAMMALIAN CELL TYPES Avoid the hassle of searching for a buffer kit that will work with your cell line. We have simplified the process with one buffer kit that is compatible with over 150 mammalian cell lines. We recommend using Invitrogen Neon NxT Resuspension R Buffer at voltages below 1,900 V and Invitrogen Neon NxT Resuspension T Buffer at higher voltages. TIME-SAVING PLATE SETUP Rather than adjusting electroporation parameters between samples with Quick Start, set up an entire plate beforehand using the Neon NxT Electroporation System’s intuitive user interface. Monitor progress on the screen as you electroporate each of your samples, and electroporate up to 24 samples in less than 20 minutes. MINIMIZE SAMPLE TRANSFER LOSS AND CONTAMINATION RISK OF VALUABLE CELLS WITH UNIQUE AND COMPACT ELECTROPORATION INSTRUMENT DESIGN MINIMAL SAMPLE TRANSFER LOSS Your samples are precious, but some volume is inevitably lost during transfer to and from a conventional electroporation cuvette. Electroporation on the Neon NxT Electroporation System occurs within the pipette tip, helping to minimize sample loss and the amount of shear force experienced by cells. MINIMAL SAMPLE CONTAMINATION The compact footprint of the Neon NxT system, including the pulse generator and pipette station, makes it small enough to fit in most biosafety cabinets (BSCs). Your samples always stay within the aseptic area while using the instrument, helping reduce the risk of contaminating precious cells. The Neon NxT system also has a new cable management feature that makes using it in the BSC hassle-free. Figure 5. Dimensions of the Neon NxT Electroporation System. The Neon NxT pulse generator (9.5 in. W x 7.6 in. H x 9.9 in. D) and Neon NxT pipette station (4.9 in. W x 11.5 in. H x 5.9 in. D) fit inside most BSCs, which helps minimize sample contamination. SPECIFICATION COMPARISON BETWEEN THE NEON NXT ELECTROPORATION SYSTEM AND THE NEON TRANSFECTION SYSTEM Specification Neon NxT Electroporation System Neon Transfection SystemElectroporation Volume10 µL or 100 µL10 µL or 100 µLElectroporation buffer volume*2 mL3 mLTip attachmentClipTip technologyFrictionElectroporation pulses1-101-10Pulse duration1-100 ms1-100 msPulse voltage500-2,500 V500-2,500 VArc detectionYesNoCloud connectivityYesNoPulse generator dimensions**9.5 x 7.6 x 9.9 in. (W x H x D) 11. 9 lb (5.4 kg)9.5 x 8.9 x 13.6 in. (W x H x D) 13. 8 lb (6.25 kg)Cable management feature***YesNoTouch display8-inch capacitive touchscreen7-inch touchscreenElectrical rating100-240 VAC, 270 W100-240 C, 150 W *The buffer tube of the Neon NxT Electroporation System has a 2 mL level indicator. **The Neon NxT pulse generator can be moved into or out of a typical BSC without removing the sash. ***Excess cable length can be secured behind the Neon NxT system with the attachable cable organizer. THE SAME TECHNOLOGY AND PERFORMANCE AS THE NEON TRANSFECTION SYSTEM Figure 6. Performance of the Neon NxT Electroporation System and the Neon Transfection System. Performance was evaluated by transfecting different mammalian cell lines with GFP plasmid DNA or GFP mRNA. (A) GFP plasmid DNA transfection efficiency reported as the percentage of GFP-positive cells. (B) Viability of cells after transfection with GFP plasmid DNA. (C) GFP mRNA transfection efficiency reported as the percentage of GFP-positive cells. (D) Viability of cells after transfection with GFP mRNA. -------------------------------------------------------------------------------- † Kim JA, Cho K, Shin MS, et al. (2008) A novel electroporation method using a capillary and wire-type electrode. Biosens Bioelectron 23(9):1353–1360. GIBCO CTS XENON ELECTROPORATION SYSTEM FOR CELL THERAPY MANUFACTURING A closed, scalable electroporation system for GMP-compliant cell therapy manufacturing. Process- and protocol-compatible with the Neon NxT Transfection System, the Xenon system helps enable smooth scale-up from research to process development to commercial manufacturing of up to 25 mL at a time. Learn more Resources Documents * Quick reference guide: Neon NxT Electroporation System * Specification Sheet: Neon NxT Electroporation System * User Guide: Neon NxT Electroporation System * Infographic Flyer: Invitrogen Neon NxT Electroporation System * Application note: Achieve exceptional genome editing efficiency with the Neon NxT Resuspension Genome Editing Buffer * Application note: Streamlining the electroporation workflow with Neon NxT Electroporation System: a comparative study with the Neon Transfection System * Neon Transfection Instrument Discontinuation Letter TRANSFECTION PROTOCOLS AND CITATIONS Search this library to find protocols and citations curated to fit your experimental needs. Filter by cell type, payload, and product of choice to easily unlock your answers. Explore protocols and citations Cell Culture and Transfection Learning Center Access cell culture and transfection application resources for more success as you plan and execute your experiments. Support * Services and Support * Visit our Instrument Service Coverage Lookup page to check your existing service coverage and renew TRANSFECTION FAQS Search our extensive collection of Transfection FAQs to find the answers related to Neon Electroporation Transfection. See electroporation FAQs See Neon system FAQs SOFTWARE UPDATES Download the latest software for the Neon NxT Electroporation System * Release note * Neon NxT Instrument Firmware 1.1.0 For Research Use Only. Not for use in diagnostic procedures. Stylesheet for Classic Wide Template adjustments Ordering Plus Icon Minus Icon * Order Status * Order Help * Quick Order * Supply Center * eProcurement Support Plus Icon Minus Icon * Help and Support * Contact Us * Technical Support Centers * Documents and Certificates * Report a Site Issue Resources Plus Icon Minus Icon * Check Order Status * Order Support * Training * Webinars * Blog * Social Media * Contact Us * Report a Site Issue About Thermo Fisher Plus Icon Minus Icon * About Us * Careers * Investors * News * Social Responsibility * Trademarks * Accessibility for Ontarians with Disabilities Act Our Portfolio Plus Icon Minus Icon * Thermo Scientific * Applied Biosystems * Invitrogen * Gibco * Ion Torrent * Fisher Scientific * Unity Lab Services * Patheon * PPD * Terms & Conditions * Privacy Policy * Price & Freight Policy * Cookie Preferences Your choices regarding cookies on this site We and our affiliates and vendors use cookies and similar technologies to operate our sites, recognize visitors to our sites, provide secure log-in, collect statistics to optimize site functionality, and deliver content tailored to your interests. Click Accept All to accept all cookies and go directly to the site, or click on Manage Settings to see detailed descriptions of the types of cookies and choose whether to accept certain cookies while on the site. Manage Settings Accept All © Copyright 2006-2024 Thermo Fisher Scientific Inc. All rights reserved Canada Buy 3 cases, receive 2 cases at no additional charge. Exclusions apply Order now ×