ARC FLASH SUITS

The protection provided from Du Pont Nomex Arc Flash suites gives a person the
benefit
of a few seconds to escape the Arc flash, by preventing the burning of skin. The
main
characteristic of Nomex material is to self extinguish.
( FR – Inherently flame retardant – not treated).






A REAL LIFE SAVER

Live Line Technology  , Arc flash suits are light-weight , inherently flame
Retardent and will save a persons life against an arc flash.




HEAD TO TOE PROTECTION

The electrician should always wear total body protection from head to toe,
including – Jacket, Trouser, Hood, Glove in a Bag.




CARING FOR YOUR GARMENTS

Arc flash suits , need to be carefully cleaned. Do not use detergents and
excessive hot water when cleaning arc suits. Store them safely in a bag which is
provided by Live Line Technology.




DUPONT™ NOMEX® FIBRE IS INHERENTLY FLAME-RESISTANT




DuPont™ Nomex®  fibre is inherently flame-resistant, will not melt or drip, and
does not support combustion in the air, thus providing excellent arc flash
protection. And because the protection is woven right into Nomex® garments, it
cannot wear off of wash out over time.

When exposed to the intense heat typical of electric arc, Nomex® fibre
carbonises and thickens. This increases the protective barrier between the heat
source and the wearer’s skin and helps minimise burn injury.


GET TO KNOW OUR ARC FLASH SUITS



1


SIZES:
Small – 5XL
(prices do vary according to size).

2


COLOUR RANGE:
Olive, Black, Navy blue, Orange

3


FABRIC:
Blended 33% Nomex/Kevlar, 66% Modacruylic &
2% Antistatic liners. TRIPLE LAYER

4


ATPV¹ range:
from 12 cal/cm to 140 cal/cm²


5


SPECIFICATION:
ASTM F1959/ 1959M ASTM F1506;
NFPA 70E;
SANS 724.

1


SIZES:
Small – 5XL
(prices do vary according to size).

2


COLOUR RANGE:
Olive, Black, Navy blue, Orange

3


FABRIC:
Blended 33% Nomex/Kevlar, 66% Modacruylic &
2% Antistatic liners. TRIPLE LAYER

4


ATPV¹ range:
from 12 cal/cm to 140 cal/cm²


5


SPECIFICATION:
ASTM F1959/ 1959M ASTM F1506;
NFPA 70E;
SANS 724.



Nomex Arc flash suites should always be worn when operating high voltage systems
for example 11kv, 22kv or 33kv systems in applications such as switchgear inside
Substations. (eg. 132kv/11kv) This is to protect against the potential hazard of
an arc flash.

The correct arc flash risk assessment needs to be carried out before an ATPV –
Arc Thermal Performance value can be determined. The greater the ATPV value.


FEATURES:



 * Light weight.
   
   
   
 * Material: Multi-layer DuPont™ Nomex® / DuPont™ Kevlar® / Modacrylic
   
   
   
 * Guaranteed flame resistant for the life of the garment.
   
   
   
 * Machine washable.
   
   
   

 * Excellent breathability.
   
   
   
 * Cool cotton comfort.
   
   
   
 * Arc Flash Jacket designed to interface with Arc Flash Hood.
   
   
   




LLT SAVE ARC FLASH RATINGS :




An electrical arc flash is more severe with higher voltages & higher fault level
ratings of the equipment (switchgear) substation. The greater the flash, the
greater the severity of the radiation exposed to the operator.  It is imperative
to get the correct grading of the Nomex Flash suite to ensure the necessary
protection against radiation of the Arc flash.


LLT SAVE ARC THERMAL PERFORMANCE VALUES (ATPV) :

• 12+ CAL. (Conti)
• 21+ CAL (Conti )
• 25+ CAL. (Conti)
• 55+ CAL Arc
• 65+ CAL.
• 100 + CAL.
• 140 + CAL.

Arc Thermal Performance value (ATPV value) is presented in calories per
centimeter square and represents the maximum capability possible from an arc
flash protection for particular clothing.




CHARACTERISTICS OF ARC FABRIC :






ABSORBS HEAT ENERGY

The fiber itself absorbs heat energy during the carbonization process.




ELIMINATE AIR MOVEMENT AND HEAT TRANSFER

The fibers eliminate air movement and heat transfer to the interior skin area.




INSULATING BARRIER

An insulating barrier reduces heat transfer to the person.




ARC FLASH CLOTHING CATEGORIES: NFPA 70 E STANDARD CODE




Hazard CategoryClothing descriptionATPV ValueCategory HRC 0Non-melting,
flammable materials(untreated cotton, wool, rayon, silk or blends. A fabric with
4.5 ouncesNo ATPV valueCategory HRC 1FR shirts and FR pants or FR coveralls, 4
CAL/cm2. 4 – 8 Cal/cm²Category HRC 2Cotton underwear, conventions l shirts,
trouser, plus FR shirts, FR trouser or FR coveralls8 – 25 Cal/cm²
Category HRC 3Cotton underwear, plus FR shirt, FR trouser and FR coveralls.25 –
40 Cal/cm²
Category HRC 4Cotton underwear, plus FR shirt, FR trouser and multi-layered