Skip to content
 * Home
 * Products
   * Product Benefits
   * Product Details
 * Nuclear
 * Resources
   * Videos
   * Publications
   * Press Releases
   * Tutorials
   * Datasheets
 * About RTP
   * Why Choose RTP
   * Careers
   * Contact RTP
 * Request a Quote




Ready to trade up

High Performance – 1 Msec scan rate (logic solving, communications, and
diagnostics). 1 Msec time stamp for both S.O.E. and Alarms (both Analog and
Digital).
True Redundancy – No switchover as both processors solve logic independently and
vote the results.
Advanced Diagnostics – Consistent with diagnostics found in advanced safety
systems (IEC61508), virtually eliminates down time
Easy to Program – Object oriented programming per IEC61131-3, supports on-line
bump-less changes. Configure as Single, Dual Redundant or Triple Redundant
without extra software. I/O can be configured independently.
Unlimited Expansion – A single chassis supports up to 224 Analog/Digital I/O
points. The system easily expands as the requirements grow to over 100,000 I/O
points.
One-Time Registration fee – Pay for NetSuite D once and have an unlimited use of
all the software applications associated with NetSuite across your plant. No
hardware or software keys.
Cost – An RTP3400 chassis, consisting of 7 Analog/Digital I/O cards, lists for
less than $5,000.  A one-time registration fee of $2,500 gets you an unlimited
use copy of NetSuite D.

Note: Interested Manufactures Representatives contact RTP


50+ YEARS OF TECHNICAL EXCELLENCE

We solve Data Acquisition, Critical Control, and Safety Requirements in the
Nuclear Power, Process Control, and Safety Markets.

About RTP
Previous
SIL-3 TMR
Product Highlights RTP3000 TAS N+
The RTP3000 Tas N+ can be applied as a stand-alone safety controller SIS, as a
distributed control system DCS, or both applications can be combined into a
single controller .
Read More
SIL-3 TMR
Product Highlights Reduced Capital Costs
 * 40% Less than conventional DCS Systems
 * Site License on Comprehensive Software Suite

Read More
SIL-3 TMR
Product Highlights Reduced Operating Costs
 * Free Software Updates
 * Free Technical Support

Read More
Next
Costs Less
RTP entered the safety market with a stated goal to bring down the cost of a
safety system
View Details
Runs Faster
5 msec reaction time (screw to screw) based on a scan time of 1 msec, including
solving 30 PID loops per node
View Details
Never Stops
Based on the failure rates defined in IEC61508 : 2010, the TAS system in a quad
configuration has an MTTFS of greater then 60,000 years
View Details
NUCLEAR


BEST PRACTICES IN PLANT RELIABILITY & PERFORMANCE

Owned and operated by American Electric Power, the Donald C. Cook Nuclear Plant
is located on 650 acres along Lake Michigan’s eastern shoreline in Berrien
County, Michigan.

Read More
Donald C. Cook Nuclear Plant, Michigan


LATEST RESOURCES

VIEW ALL
PDF
TAS User Benefits 8-24
The RTP3000-TAS provides processing power capable of solving in excess of 50 PID
control loops …
PDF
Exida – Architecture White Paper RTP3000
The RTP 3000 SIS System has a hybrid architecture that uses a set of advanced
de…
PDF
TÜV Markov Report
This report summarizes the analysis of the RTP3000 system by means of Markov
Modelling. By usin…


TESTIMONIALS

Previous
"Excerpt from the Exida White Paper: A Hybrid Fault Tolerant Architecture & New
Levels of Performance, Availability and Safety Integrity

The RTP 3000 SIS System has a hybrid architecture that uses a set of advanced
design techniques to provide SIL 3 safety integrity and high availability.
Safety integrity and high availability are achieved on a system that also
provides an unusual level of architecture flexibility and computing speed (12
msec. scan rates). This combination of safety integrity, high availability,
flexibility and performance sets new levels of expectation among safety … Read
MorePLC users.

A Markov model was developed to analyze the behavior of the RTP 3000 SIS system
under fault conditions for two common configurations. Using the Markov models
and the failure rates from the FMEDA, example average Probability of Failure on
Demand (PFDAVG) and Mean Time To Fail Spurious (MTTFS) values are calculated.
The results confirm the level of high safety integrity and high availability
achieved by the design."
Dr. William M Goble P.E., CSF
"The RTP data acquisition cards were installed and have been running in our
plant unit 2, since 1987. In that entire running time, on 24×7 basis, we have
had only one card failure. This is a remarkable achievement considering the
environment these cards have been running in and that, during 2001, we also
replaced the computer system, all the display stations and upgraded the network.
They ALL became obsolete, but we kept the RTP I/O which is still to this date,
flawlessly performing its functions. This was the main reason that when it came
time to upgrade the unit 3 plant process computer, … Read Morethe plant decided
to stay with RTP. Their equipment is reliable, durable and is withstanding the
test of time."
Alfred Genadry – Entergy, Indian Point Energy Center
"We looked at several TUV/SIL rated system manufacturers and chose RTP based on
the fact that RTP was the only one that could provide everything that our
clients were looking for."
Alan Mowat, General Manager, Tyco Fire & Integrated Solutions, Ltd.
"During periodic maintenance at BaoSteel’s 2030 cold strip CM09 color coating
machine group, primary and secondary replacement ovens from the Stein Heurtey
Corporation of France were scheduled for installation. Other replacement
equipment included the incinerator, dry air supply and flue gas systems. After
evaluating several industrial control systems from different venders, Stein
Heurtey and BaoSteet selected the RTP 2200 Hybrid Control System and Citect (Ci
Technologies, Inc.) as the primary control system for the machine group."
BaoSteel Automation System
View Case Study
"The desulfurization and sulfuric acid equipment previously used by BaoSteel
Chemical Ltd. was imported from NKK Japan and based on Foxboro’s Spectrum
control system. BaoSteel was facing a Y2K problem with the Spectrum control
system and maintenance costs were escalating. In order to optimize the process,
decrease operation costs, and increase profits, in November 1999 it was decided
to upgrade the control sytem. The new control sytem includes the latest
generation RTP 2200 Hybrid Control System, which combines the advantages of both
the PCL and DCS. This system includes redundant I/O car … Read Mores, I/O buses,
target node controllers, power supplies, network communication interfaces,
Citect I/O servers, and Citect I/O operation stations."
BaoSteel Chemical Desulfurization Control System
View Case Study
"During periodic maintenance at BaoSteel’s 2030 cold strip CM09 color coating
machine group, primary and seconday replacement ovens from the Stein Heurtey
Corporation of France were scheduled for installation. Other replacement
equipment included the incinerator, dry air supply and flue gas systems. After
evaluating sever industrial control system from different venders, Stein Heurtey
and BaoSteel selected the RTP 2200 Hybrid Control System and Citect (Ci
Technologies, Inc.) as the primary control system for the maching group."
BaoSteel Cold Strip Control System
View Case Study
"The 135 Ton/Hour Boiler Computer-Control System at BaoSteel’s Energy Department
is using the new generation RTP 2200 HCS (Hybrid Control System), which combines
the features and benefits of the PLC and DCS. This system includes full
redundancy of I/O cards, I/O buses, CPUs, power supplies, network
communications, Citect I/O servers, and Citect I/O operation stations."
BeoSteel Boiler Control System
View Case Study
"The solid waste incinerator at the Southerly Wastewater Treatment Plant,
located just south of the City of Columbus, Ohio, was previously operated using
a circa 1970’s vintage control system. Beyond its useful life and subject to Y2K
issues, management decided to replace the system. Requirements included a
simplified configuration and programming environment, minimal time to install
and commission, and an open architecture non-obsolescent design that was easy to
operate and maintain. The goal was to acquire a high-performance, accurate, and
stable control system that would help the city … Read Moreo reduce costs
associated with operating the incinerators. Over twenty PLC and DCS vendors
competed in the bid process. After careful evaluation, the project was awarded
to the Coleman Instrument Company of Cincinnati, Ohio in October 1999.
Installation of the new system began in December and completed the first week of
February 2000."
City of Columbus Incinerator Control System
View Case Study
"New measurement systems have been installed at the Forsmark Sweden nuclear
power plant. These systems collect operational data from two of the plant’s
three reactors. Each system consists of approximately one thousand 0-10V analog
points, which are collected by the data collection nodes located throughout the
facility."
Forsmark Nuclear Power Plant Monitoring System
View Case Study
"The control system for six 220-ton boilers and three 100MW turbines at the
Fuxin power plant was using legacy analog instruments, which were reaching the
end of their life expectancy and malfunctioning more frequently. The system
upgrade was awarded to Citect (Ci Technologies Inc) in June 1999. The new
control system uses RTP’s 2200 HCS (Hybrid Control System), which combines the
features and benefits of the PLC and DCS. Full redundancy is provided for I/O,
busses, controllers, power supplies, network communications, Citect I/O servers,
and Citect I/O operator stations. After the control … Read Moresystem was
updated, total automation of head main steam control of six boilers, DEH
(Digital Electrical Hydrodynamic) control of the six turbines, network
communications, and data sharing of whole system were successfully implemented."
Fuxin Power Turbine Control System
View Case Study
"Product designers and end users can both benefit when a solution uses open
standard components, as demonstrated by the design of a system to monitor
vibration in power turbines. The user benefits from having an assured upgrade
path and maintenance capabilities that can be independent of arbitrary
technology changes and from price increases or policies imposed by a
manufacturer who may be indifferent to the market in which the user exists.
Future upgrades can be incremental, using installed sensors, rather than
requiring capital investments to replace entire systems. Use of open standard
compon … Read Morents enables the product designer to concentrate time and
resources on adding the intellectual property that constitutes their chief value
added benefit. This means he can also incorporate the latest technology and
achieve high speed-to-market, both of which create a competitive advantage over
proprietary solutions."
Montenay Pacific Power
View Case Study
"Qinghe Power Plant is located in Qinghe, Tielin County, LiaoNing Province,
China. With maximum capacity of 1,200 MW, it was formerly one of the largest
power plants in China. In 1999, the decision was made to upgrade its chemical
water treatment plant instrumentation. The job was awarded to Citect (Ci
Technologies Inc, Shanghai). After upgrading the system, the level of automation
at the water treatment plant has increased, while process costs have decreased,
and profits retrieved by the project ahave met the plant’s investment
expectations.

Citect uses the new generation RTP 220 … Read More Hybrid Control System to
monitor and control the entire process, to guarantee the continuous BFW (Boiler
Feeder Water) supply to the boilers as well as normal running of the boilers,
turbines and power generator system."
Qinghe Power Plant Water Treatment Control System
View Case Study
Next
We're out to change the world of control
and safety systems one customer at a time.
Contact Us
Quicklinks
 * Home
 * Nuclear
 * Request a Quote

Products
 * Product Benefits
 * Product Details

Resources
 * Videos
 * Publications
 * Press Releases
 * Tutorials
 * Datasheets

About RTP
 * Why Choose RTP
 * About RTP
 * Careers
 * Contact RTP

RTP Corp.
2832 Center Port Circle
Pompano Beach, FL 33064
(954) 597-5333 contact@rtpcorp.com

2024 © Copyright All Rights Reserved