www.copraudit.com
Open in
urlscan Pro
185.2.5.23
Public Scan
Submitted URL: https://r.coprotec-communication.net/mk/cl/f/2I2-ONv7CC9tDHcpcL10j_arf3FC6ptITrKRGB4bpqYi1RHTk_QYLxsT7BiTEwQDzSpT0T8DGe5lBy7pF-X9BbB2...
Effective URL: https://www.copraudit.com/ventilation-appareil-b23p-qt-36-2/?utm_source=sendinblue&utm_campaign=Newsletter%20Copraudit%20J...
Submission: On August 19 via api from IE — Scanned from DE
Effective URL: https://www.copraudit.com/ventilation-appareil-b23p-qt-36-2/?utm_source=sendinblue&utm_campaign=Newsletter%20Copraudit%20J...
Submission: On August 19 via api from IE — Scanned from DE
Form analysis
2 forms found in the DOMGET https://www.copraudit.com/
<form class="responsive-searchform" method="get" action="https://www.copraudit.com/"> <input type="text" class="text-input" value="" name="s" id="s" placeholder="Recherche...">
<i><input value="" type="submit"><svg class="mk-svg-icon" data-name="mk-icon-search" data-cacheid="icon-62ff34f2b5060" xmlns="http://www.w3.org/2000/svg" viewBox="0 0 1664 1792"><path d="M1152 832q0-185-131.5-316.5t-316.5-131.5-316.5 131.5-131.5 316.5 131.5 316.5 316.5 131.5 316.5-131.5 131.5-316.5zm512 832q0 52-38 90t-90 38q-54 0-90-38l-343-342q-179 124-399 124-143 0-273.5-55.5t-225-150-150-225-55.5-273.5 55.5-273.5 150-225 225-150 273.5-55.5 273.5 55.5 225 150 150 225 55.5 273.5q0 220-124 399l343 343q37 37 37 90z"></path></svg></i>
</form>
GET https://www.copraudit.com/
<form method="get" id="mk-fullscreen-searchform" action="https://www.copraudit.com/"> <input type="text" value="" name="s" id="mk-fullscreen-search-input">
<i class="fullscreen-search-icon"><svg class="mk-svg-icon" data-name="mk-icon-search" data-cacheid="icon-62ff34f2bb467" style=" height:25px; width: 23.214285714286px; " xmlns="http://www.w3.org/2000/svg" viewBox="0 0 1664 1792"><path d="M1152 832q0-185-131.5-316.5t-316.5-131.5-316.5 131.5-131.5 316.5 131.5 316.5 316.5 131.5 316.5-131.5 131.5-316.5zm512 832q0 52-38 90t-90 38q-54 0-90-38l-343-342q-179 124-399 124-143 0-273.5-55.5t-225-150-150-225-55.5-273.5 55.5-273.5 150-225 225-150 273.5-55.5 273.5 55.5 225 150 150 225 55.5 273.5q0 220-124 399l343 343q37 37 37 90z"></path></svg></i>
</form>
Text Content
* ACCUEIL * CC Gaz * CC1 : Certificat de conformité gaz modèle 1 * CC2 : Certificat de conformité gaz modèle 2 * CC2 Intox : Certificat de conformité gaz spécial Intox * CC2 BAILLEUR : Certificat de conformité gaz modèle 2 bailleur * CC3 : Certificat de conformité gaz modèle 3 * Comment acheter un certificat de conformité gaz ? * Comment devenir PGI ? * Audits * Audit Gaz * Audit Isolation * Audit Qualibat RGE * Audit Qualit’EnR RGE * Audit Qualifelec RGE * Documents * FAQ * Actus * Notes d’information * Offres d’emploi * Questions techniques gaz * Fiches Techniques Gaz * Contact * Connexion * ACCUEIL * CC Gaz * CC1 : Certificat de conformité gaz modèle 1 * CC2 : Certificat de conformité gaz modèle 2 * CC2 Intox : Certificat de conformité gaz spécial Intox * CC2 BAILLEUR : Certificat de conformité gaz modèle 2 bailleur * CC3 : Certificat de conformité gaz modèle 3 * Comment acheter un certificat de conformité gaz ? * Comment devenir PGI ? * Audits * Audit Gaz * Audit Isolation * Audit Qualibat RGE * Audit Qualit’EnR RGE * Audit Qualifelec RGE * Documents * FAQ * Actus * Notes d’information * Offres d’emploi * Questions techniques gaz * Fiches Techniques Gaz * Contact * Connexion QUESTION TECHNIQUE GAZ N°36 Par Lucie CHOPELIN Publié le 7 juillet 2022 Dans Questions techniques Question technique gaz n°362022-07-072022-07-07https://www.copraudit.com/wp-content/uploads/2018/04/copraudit_hd-blanc-e1567430814891.pngCOPRAUDIThttps://www.copraudit.com/wp-content/uploads/2022/07/illustration-qt-36_fiche-gaz-31.png200px200px * * * * * A QUELLE EXIGENCES, EN MATIÈRE DE VENTILATION, DOIT RÉPONDRE LE LOCAL DANS LEQUEL EST INSTALLÉ UN APPAREIL GAZ DE TYPE B23P ? -------------------------------------------------------------------------------- L’évacuation de l’air vicié d’effectuant par le biais du conduit vertical débouchant en toiture, l’amenée d’air pourra être directe ou indirecte. Elle pourra être implantée à n’importe quelle hauteur et sa section est fonction de la puissance installée. Pour une habitation datant d’avant 1969, la section de l’amenée d’air est déterminée par le tableau ci-dessous : Pu ≤ 25 kW : S = 50 cm² 25 kW < Pu ≤ 35 kW : S = 70 cm² 35 kW < Pu ≤ 50 kW : S = 100 cm² 50 kW < Pu ≤ 70 kW : S = 150 cm² Pour une habitation datant d’après 1969 ou après réhabilitation de l’enveloppe du bâtiment, les réglettes d’entrée d’air dans les menuiseries des pièces principales peuvent être utilisées comme amenée d’air indirecte. Dans ce cas, ce n’est plus la section qui est prise en compte mais la somme des modules d’entrée d’air, celle-ci devant alors être au moins égale à 6,2 fois la puissance utile de la chaudière. Exemple : Pour une chaudière de 24 kW ceci représente 6,2 x 24 = 148,8 m3/h, soit 5 réglettes de 30 m3/h. Il faudra dans ce cas également veiller au détalonnage des portes.[/vc_row] Télécharger la fiche question technique * Recrutement * Politique de confidentialité * Mentions légales * Plan du site MENU PRINCIPAL * Accueil * CC Gaz * Audits * Documents * FAQ * Actus * Contact * Connexion NOS PARTENAIRES * COPROTEC * HabitA+ * L'émotion GAZ CONDITIONS GÉNÉRALES DE VENTE Télécharger les conditions générales de vente Gaz Télécharger les conditions générales de vente Isolation * COPRAUDIT * 12, impasse Montgolfier CS40010 68025 SAINTE CROIX EN PLAINE CEDEX * 03 89 71 71 58 * contact@copraudit.com * www.copraudit.com NOTRE APPLICATION MOBILE © Copyright COPRAUDIT 2022 Commencez à taper et appuyez sur Entrée pour rechercher Question technique gaz n°35Questions techniques