datacenter-group.com Open in urlscan Pro
2001:8d8:100f:f000::200  Public Scan

Submitted URL: https://www.dc-itsafe.com/
Effective URL: https://datacenter-group.com/de/leistungen/products/dc-itsafe/dc-it-safe-56-he-62-he/
Submission: On December 03 via automatic, source certstream-suspicious — Scanned from US

Form analysis 2 forms found in the DOM

POST /de/suche/?tx_indexedsearch_pi2%5Baction%5D=search&tx_indexedsearch_pi2%5Bcontroller%5D=Search&cHash=578ac425ee2bfd2a5edbaa0947b4e1a8

<form method="post" class="search-form d-flex" action="/de/suche/?tx_indexedsearch_pi2%5Baction%5D=search&amp;tx_indexedsearch_pi2%5Bcontroller%5D=Search&amp;cHash=578ac425ee2bfd2a5edbaa0947b4e1a8">
  <div>
    <input type="hidden" name="__referrer[@extension]" value="">
    <input type="hidden" name="__referrer[@controller]" value="Standard">
    <input type="hidden" name="__referrer[@action]" value="productDetail">
    <input type="hidden" name="__referrer[arguments]" value="YTowOnt9e9224c488bd2a12034ad011dd14aa2fb45d226ea">
    <input type="hidden" name="__referrer[@request]" value="{&quot;@extension&quot;:null,&quot;@controller&quot;:&quot;Standard&quot;,&quot;@action&quot;:&quot;productDetail&quot;}0e63298f26ed6070a04a2a54fb7c332d766f06db">
    <input type="hidden" name="__trustedProperties" value="{&quot;tx_indexedsearch_pi2&quot;:{&quot;search&quot;:{&quot;sword&quot;:1}},&quot;0&quot;:1}42f5c40c15c5c545febe19945d13c139396c1621">
  </div>
  <div class="input-group search-input">
    <input placeholder="Suchbegriff eingeben ..." class="form-control" style="margin-right: 1rem !important" type="text" name="tx_indexedsearch_pi2[search][sword]">
    <div>
      <button class="btn btn-primary ml-auto" type="submit" name="" value="">Suchen <span class="icon">
          <svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 6 10">
            <path d="M6 5L1 10 0.3 9.3 4.6 5 0.3 0.7 1 0z"></path>
          </svg>
        </span>
      </button>
    </div>
  </div>
</form>

POST /de/suche/?tx_indexedsearch_pi2%5Baction%5D=search&tx_indexedsearch_pi2%5Bcontroller%5D=Search&cHash=578ac425ee2bfd2a5edbaa0947b4e1a8

<form method="post" class="search-form d-flex" action="/de/suche/?tx_indexedsearch_pi2%5Baction%5D=search&amp;tx_indexedsearch_pi2%5Bcontroller%5D=Search&amp;cHash=578ac425ee2bfd2a5edbaa0947b4e1a8">
  <div>
    <input type="hidden" name="__referrer[@extension]" value="">
    <input type="hidden" name="__referrer[@controller]" value="Standard">
    <input type="hidden" name="__referrer[@action]" value="productDetail">
    <input type="hidden" name="__referrer[arguments]" value="YTowOnt9e9224c488bd2a12034ad011dd14aa2fb45d226ea">
    <input type="hidden" name="__referrer[@request]" value="{&quot;@extension&quot;:null,&quot;@controller&quot;:&quot;Standard&quot;,&quot;@action&quot;:&quot;productDetail&quot;}0e63298f26ed6070a04a2a54fb7c332d766f06db">
    <input type="hidden" name="__trustedProperties" value="{&quot;tx_indexedsearch_pi2&quot;:{&quot;search&quot;:{&quot;sword&quot;:1}},&quot;suche&quot;:1}f289e611c0d98e0d44b1b97e778575576e346fc3">
  </div>
  <div class="input-group">
    <input placeholder="Suchbegriff eingeben ..." class="form-control" style="margin-right: 1rem !important" type="text" name="tx_indexedsearch_pi2[search][sword]">
    <div>
      <button class="btn btn-primary mobile-search-nav ml-auto" type="submit" name="suche" value="">
        <svg xmlns="http://www.w3.org/2000/svg" width="16" height="16" viewBox="0 0 32 32">
          <path d="M29,27.5859l-7.5521-7.5521a11.0177,11.0177,0,1,0-1.4141,1.4141L27.5859,29ZM4,13a9,9,0,1,1,9,9A9.01,9.01,0,0,1,4,13Z" transform="translate(0 0)"></path>
        </svg>
      </button>
    </div>
  </div>
</form>

Text Content

 * Branchenlösungen
 * News & Stories
 * Unternehmen
 * Downloads
 * Karriere
 * Kontakt
 * 
 * DE
   EN

 * Consulting
 * Engineering
 * Construction
 * Products
 * Services
 * Solutions

NEWS & STORIES

 * Alle
 * Referenzen
 * News
 * Themen
 * Events



UNTERNEHMEN

 * Über uns
 * Management
 * Partner und Verbände
 * Nachhaltigkeit
 * Qualität
 * Ansprechpartner
 * Kontakt

 * Nachhaltigkeit
 * Energieeffizienzgesetz
 * Forschungskooperationen
 * Recycling und nachhaltige Baustoffe
 * Abwärmenutzung
 * Blauer Engel

 * Qualität
 * Normen und Zertifizierungen
 * Bestens geschützt

 * National
 * International
 * Partnernetzwerk
 * Partner werden

DOWNLOADS

 * Übersicht
 * DC Mag
 * Broschüren
 * Maßblätter
 * Ausschreibungstexte



KARRIERE

 * Berufserfahrene
 * Ausbildung und duales Studium



KONTAKT


Suchen

CONSULTING

 * Analyse
 * Strategie
 * Projektentwicklung
 * Energie-und Umweltmanagement
 * Dokumentation und Handbücher
 * Zertifizierungsbegleitung

Consulting

Wir beraten Sie bei Ihrem sicheren, effizienten und wirtschaftlichen
Rechenzentrum

Analyse

Wir erstellen ein unabhängiges Bild Ihrer Infrastruktur als Basis für all Ihre
Entscheidungen

STRATEGIE

Mithilfe unserer Strategiebausteine unterstützen wir Sie bei der Ausrichtung
Ihrer IT und erkennen und bewerten die wichtigsten Einflussfaktoren - auf alle
aktuellen sowie künftigen Anforderungen zugeschnitten

 

PROJEKTENTWICKLUNG

Wir prüfen die Rahmenbedingungen, haben Normen und Standards im Blick und
entwickeln ein Konzept - mit allen notwendigen Dokumenten

ENERGIE- UND UMWELTMANAGEMENT

Wir decken Schwachstellen und Potenziale beim Thema Energieverbrauch und -bedarf
auf, erschließen Fördermittel und begleiten Sie durch Audits und
Zertifizierungen - bis hin zur Implementierung eines Energiemanagementsystems 

Dokumentation und Handbücher

Analyse und Dokumentation des Ist- und Sollzustandes Ihrer IT-Infrastruktur im
Bereich Dokumentationsmanagement, Strukturen, Abläufe und Prozesse zur
Verringerung der Unternehmens- und Haftungsrisiken für Management und IT-Leitung

 

ZERTIFIZIERUNGSBEGLEITUNG

Ob Umwelt-Gütezeichen, Zertifizierungen als Vorausetzung zur Kundengewinnung
oder Vorgabe von Ihrem Versicherer - wir begleiten Sie von Anfang an durch den
Prozess

ENGINEERING

 * Architektur
 * Technische Gebäudeausrüstung (TGA)

Engineering

Wir planen Ihr Rechenzentrum komplett aus einer Hand - unabhängig von Branche,
Infrastruktur, Location und Neu- oder Modellbau

Architektur

Wir planen eine nachhaltig ausgerichtete Architektur für Ihr Vorhaben

Technische Gebäudeausrüstung (TGA)

Die richtige Konzeption und Optimierung technischer Anlagen trägt mit der
fachmännischen Planung der TGA zu einer maximalen Energieeffizienz bei

CONSTRUCTION

 * Generalunternehmerschaft
 * Generalübernehmerschaft
 * Data Center Lösungen
 * Data Center Komponenten
 * Rechenzentrums-Konfigurator

Construction

Wir kümmern uns um die Realisierung von Rechenzentren und den Schutz Ihrer
IT-Infrastrukturen, die auf Ihre individuellen Bedürfnisse abgestimmt sind

Generalunternehmerschaft

Sie haben den Plan, wir führen ihn aus - bis zur schlüsselfertigen Übergabe

 

Generalübernehmerschaft

Alles aus einer Hand - komplette und zuverlässige Umsetzung Ihres Projektes

 

Data Center Lösungen

Wir bieten Ihnen zeitgemäße und nachhaltige Umsetzungsvarianten - ob modular,
plug-and-play oder CO2-neutral

Data Center Komponenten

Wir kümmern uns um jeden passenden Baustein bei Ihrer Rechenzentrumsplanung -
umwelt-, budget- und ressourchenschonend 

Data Center Konfigurator

Ob Indoor oder Outdoor, Neubau oder Umrüstung: Wir bieten für jeden Fall Ihre
individuell passende Lösung. Und das zukunftssicher und maximal flexibel

PRODUCTS

 * DC IT Safe
 * DC IT Container
 * DC IT Room
 * DC IT Monitoring
 * DC IT Data Safes
 * DC IT Shielding
 * Produktkonfiguratoren

Products

Wir bieten Ihnen Hochsicherheitsprodukte für Ihre IT-Infrastruktur

 * DC IT Safe
 * DC IT Safe Mini
 * DC IT Safe 56 HE / 62 HE
 * DC IT Safe Konfigurator

 * DC IT Container
 * DC IT 20ft ISO Container
 * DC IT 40ft ISO Container
 * DC IT Container Individuell
 * DC IT Container Konfigurator

 * DC IT Room
 * DC IT Room Quartzite 9.0
 * DC IT Room Quartzite 9.3
 * DC IT Room Granite
 * DC IT Room Konfigurator

 * DC IT Monitoring
 * DC IT Monitoring Agent 32.2

 * DC IT Data Safes
 * DC IT DataSafes S
 * DC IT DataSafes SE

SERVICES

 * Maintenance
 * Präventivmaßnahmen
 * Controlling und Monitoring
 * Betriebskosten- und Energieoptimierung

Services

Wir kümmern uns um die Instandhaltung, Sicherheit und wirtschaftliche
Optimierung Ihrer IT-Infrastrukturen

Maintenance

Instandhaltung von Bestands- und Neuanlagen - Reduzieren möglicher Störungen und
Ausfälle, Pflege und Prüfung von Wartung- und Serviceprotokollen, mögliche
Reparaturarbeiten

Präventivmaßnahmen

Wir beugen mögliche Schwachstellen vor und decken Fehlerquellen auf, damit wir
den reibungslosen Betrieb Ihres Rechenzentrums sichern können

Controlling und Monitoring

Monitoring rund um die Uhr, 24-Stunden-Hotline exklusiv für Vertragskunden sowie
Service Level Agreement (SLA)

Betriebskosten- und Energieoptimierung

Wir analysieren Ihre aktuelle Situation und optimieren die Stellschrauben der
Betriebs- und Energiekosten zur Sicherung der Wirtschaftlichkeit und
Nachhaltigkeit Ihres Rechenzentrums

SOLUTIONS


 * Leistungen
 * Branchenlösungen
 * News & Stories
 * Unternehmen
 * Downloads
 * Karriere
 * Kontakt

DE
 * EN

Branchenlösungen

News & Stories
 * Alle
 * Referenzen
 * News
 * Themen
 * Events

Unternehmen
 * Über uns
 * Management
 * Partner und Verbände
 * Nachhaltigkeit
 * Qualität
 * Ansprechpartner
 * Kontakt

Downloads
 * Übersicht
 * DC Mag
 * Broschüren
 * Maßblätter
 * Ausschreibungstexte

Karriere
 * Berufserfahrene
 * Ausbildung und duales Studium

Kontakt
Alle
Referenzen
News
Themen
Events
Über uns
Management
Partner und Verbände
Nachhaltigkeit
 * Nachhaltigkeit
 * Energieeffizienzgesetz
 * Forschungskooperationen
 * Recycling und nachhaltige Baustoffe
 * Abwärmenutzung
 * Blauer Engel

Qualität
 * Qualität
 * Normen und Zertifizierungen
 * Bestens geschützt

Ansprechpartner
 * National
 * International
 * Partnernetzwerk
 * Partner werden

Kontakt
Übersicht
DC Mag
Broschüren
Maßblätter
Ausschreibungstexte
Berufserfahrene
Ausbildung und duales Studium
Leistungen
 * Consulting
 * Engineering
 * Construction
 * Products
 * Services
 * Solutions

Consulting
 * Consulting
 * Analyse
 * Strategie
 * Projektentwicklung
 * Energie-und Umweltmanagement
 * Dokumentation und Handbücher
 * Zertifizierungsbegleitung

Consulting
 * Consulting
 * Analyse
 * Strategie
 * Projektentwicklung
 * Energie-und Umweltmanagement
 * Dokumentation und Handbücher
 * Zertifizierungsbegleitung

Consulting
 * Consulting
 * Analyse
 * Strategie
 * Projektentwicklung
 * Energie-und Umweltmanagement
 * Dokumentation und Handbücher
 * Zertifizierungsbegleitung

Consulting
 * Consulting
 * Analyse
 * Strategie
 * Projektentwicklung
 * Energie-und Umweltmanagement
 * Dokumentation und Handbücher
 * Zertifizierungsbegleitung

Consulting
 * Consulting
 * Analyse
 * Strategie
 * Projektentwicklung
 * Energie-und Umweltmanagement
 * Dokumentation und Handbücher
 * Zertifizierungsbegleitung

Consulting
 * Consulting
 * Analyse
 * Strategie
 * Projektentwicklung
 * Energie-und Umweltmanagement
 * Dokumentation und Handbücher
 * Zertifizierungsbegleitung

Engineering
 * Engineering
 * Architektur
 * Technische Gebäudeausrüstung (TGA)

Engineering
 * Engineering
 * Architektur
 * Technische Gebäudeausrüstung (TGA)

Construction
 * Construction
 * Generalunternehmerschaft
 * Generalübernehmerschaft
 * Data Center Lösungen
 * Data Center Komponenten
 * Rechenzentrums-Konfigurator

Construction
 * Construction
 * Generalunternehmerschaft
 * Generalübernehmerschaft
 * Data Center Lösungen
 * Data Center Komponenten
 * Rechenzentrums-Konfigurator

Construction
 * Construction
 * Generalunternehmerschaft
 * Generalübernehmerschaft
 * Data Center Lösungen
 * Data Center Komponenten
 * Rechenzentrums-Konfigurator

Construction
 * Construction
 * Generalunternehmerschaft
 * Generalübernehmerschaft
 * Data Center Lösungen
 * Data Center Komponenten
 * Rechenzentrums-Konfigurator

Construction
 * Construction
 * Generalunternehmerschaft
 * Generalübernehmerschaft
 * Data Center Lösungen
 * Data Center Komponenten
 * Rechenzentrums-Konfigurator

Products
 * Products
 * DC IT Safe
 * DC IT Container
 * DC IT Room
 * DC IT Monitoring
 * DC IT Data Safes
 * DC IT Shielding
 * Produktkonfiguratoren

Products
 * Products
 * DC IT Safe
 * DC IT Container
 * DC IT Room
 * DC IT Monitoring
 * DC IT Data Safes
 * DC IT Shielding
 * Produktkonfiguratoren

Products
 * Products
 * DC IT Safe
 * DC IT Container
 * DC IT Room
 * DC IT Monitoring
 * DC IT Data Safes
 * DC IT Shielding
 * Produktkonfiguratoren

Products
 * Products
 * DC IT Safe
 * DC IT Container
 * DC IT Room
 * DC IT Monitoring
 * DC IT Data Safes
 * DC IT Shielding
 * Produktkonfiguratoren

Products
 * Products
 * DC IT Safe
 * DC IT Container
 * DC IT Room
 * DC IT Monitoring
 * DC IT Data Safes
 * DC IT Shielding
 * Produktkonfiguratoren

Products
 * Products
 * DC IT Safe
 * DC IT Container
 * DC IT Room
 * DC IT Monitoring
 * DC IT Data Safes
 * DC IT Shielding
 * Produktkonfiguratoren

Products
 * Products
 * DC IT Safe
 * DC IT Container
 * DC IT Room
 * DC IT Monitoring
 * DC IT Data Safes
 * DC IT Shielding
 * Produktkonfiguratoren

Services
 * Services
 * Maintenance
 * Präventivmaßnahmen
 * Controlling und Monitoring
 * Betriebskosten- und Energieoptimierung

Services
 * Services
 * Maintenance
 * Präventivmaßnahmen
 * Controlling und Monitoring
 * Betriebskosten- und Energieoptimierung

Services
 * Services
 * Maintenance
 * Präventivmaßnahmen
 * Controlling und Monitoring
 * Betriebskosten- und Energieoptimierung

Services
 * Services
 * Maintenance
 * Präventivmaßnahmen
 * Controlling und Monitoring
 * Betriebskosten- und Energieoptimierung

 * Data Center Group
 * Products
 * DC IT Safe
 * DC IT Safe 56 HE / 62 HE

DC IT Safe - Rückseite offen
DC IT Safe - geschlossen
DC IT Safe - offen
DC IT Safe - Explosionsgrafik



DC IT SAFE
56 HE / 62 HE


DAS MODULARE KOMPAKT­RECHEN­ZENTRUM FÜR DIE SICHERHEIT IHRER IT-INFRASTRUKTUR.


 * hochverfügbarer und -sicherer IT-Schutz
 * kompakt auf weniger als 2 m²
 * flexibel und modular erweiterbar
 * Klimageräte ausgelegt auf Dauer­betrieb
 * rocket
   sofort einsatzfähig, ab Lager lieferbar


Jetzt Konfigurieren



VOM INDUSTRIEKUNDEN ÜBER DAS GESUNDHEITSWESEN BIS HIN ZU WEITEREN BRANCHEN:
ÜBERALL DORT, WO DATEN KRITISCH SIND.

Der DC IT Safe eignet sich für kleine und mittelständige Unternehmen,
Unternehmen mit dezentralen Strukturen (Logistik- und Industrieunternehmen mit
vielen Standorten, oder Filialisten) aber auch im Healthcare-Berich für
medizinische Einrichtungen, größere Gemeinschaftspraxen oder Krankenhäuser.
Profitieren Sie vom platzsparenden Rundum-Schutz für Ihre IT-Infrastrukturen.

Den Standort Ihres Micro Data Centers – ein komplettes und redundantes
Rechenzentrum auf nur 2 m² – können Sie völlig unabhängig von den räumlichen
Gegebenheiten in Ihrem Unternehmen bestimmen. Unser Micro Data Center lässt sich
sehr gut in Industriehallen oder Untergeschoss-Etagen installieren und schützt
Ihre Daten auch unter schwierigen Bedingungen zuverlässig.


GESCHÜTZT GEGEN PHYSIKALISCHE GEFAHREN


BRANDSCHUTZ

Besonderer Brandschutz für Ihre IT nach ECB·S und EN 1047-2

EINBRUCHSCHUTZ

Schützen Sie Ihre IT-Infrastruktur vor Einbrüchen oder unerlaubtem Fremdzugriff
nach EN1627

EXPLOSIONSSCHUTZ

Nach EN 13123-2 / 13124-2 – damit Ihre IT auch im Fall der Fälle intakt bleibt.

WASSER- UND STAUBSCHUTZ

Wasser- und Staubschutz nach EN 60529 zum Schutz von Hardware und Daten.

SCHUTZ VOR TRÜMMERLAST

Sollten die tragenden Gebäude-Elemente einbrechen bleibt ihre IT weiter
geschützt.

SCHUTZ VOR VANDALISMUS

Schützen Sie Ihre IT-Infrastruktur gegen mutwillige Zerstörung.

mobile-data

SCHUTZ VOR ABSTRAHLUNG

Optimaler Schutz vor Lauschangriffen und elektromagnetischer Strahlung.

hearing

LÄRMSCHUTZ

Senken Sie den Geräuschpegel Ihres Serverraums.

SCHUTZ VOR KORROSIVEN GASEN

Beugen Sie korrosiven Zerstörungen vor.





DAS MODULARE MICRO DATA CENTER

DC IT SAFES WACHSEN MIT IHREN ANFORDERUNGEN

 * Extrem robust und sicher für den Schutz von IT-Infrastruktur und Servern on
   premises.

 * Die Micro Data Centers sind vollredundante Datacenters auf nur auf 2 m²
   Fläche mit extrem kurzer Montagezeit.

 * Die IT Safes sind modular erweiterbar und können verkettet werden. Somit
   können Sie problemlos einen kleinen IT-Raum mit mehreren Racks ausstatten.

 * DC IT Safe gibt es in zwei Höhen (56 und 62 HE), in verschiedenen
   Ausführungen und unterschiedlichen Kühlleistungen.




AUSFÜHRUNGSARTEN



Single Safe
Duo Safe
Triple Safe
Quattro Safe



AUSSTATTUNGSOPTIONEN

 

SCHOTTSYSTEME

 * Schottsysteme

 * Weichschottsysteme
 * Brandschutzhülsen
 * Hartschottsysteme



ZUTRITTSKONTROLLE MIT UND OHNE GLEICHSCHLIESSUNG

 * Zutrittskontrolle mit und ohne Gleichschließung

 * Schlüsselschloss mit Profilhalbzylinder
 * PIN-Tastatur-schloss und Profilhalbzylinder
 * Code-Karten-Schloss / Code-Karten-Beschlag
 * 2-Faktor-Authentifizierung, Voraussetzung Motorschloss je Tür



SOCKEL FÜR DC-ITSAFE

 * Sockel für DC-ITSafe

 * Sockelkonstruktion mit Brandschutz F90, Höhe 60-500mm
 * Sockelkonstruktion ohne Brandschutz, Höhe 60-500mm

RACKSYSTEM UND SCHOTTUNG

 * Racksystem und Schottung

 * 44HE Rack
 * 50HE Rack
 * Kalt-/Warm-Schottung mit zusätzlichen 12HE vertikal für ITSafe 56HE
 * Kalt-/Warm-Schottung mit zusätzlichen 12HE vertikal für ITSafe 62HE



KÜHLUNG

 * Kühlung

Kühlung mit Kältemittel R410a oder R32:

 * Außengerät, Innengerät, Zubehör bis 1,6-4,5 kW (single)
 * Außengerät, Innengerät, Zubehör bis 1,6-4,5 kW (redundant)
 * Außengerät, Innengerät, Zubehör bis 2,7-6,7 kW (single)
 * Außengerät, Innengerät, Zubehör bis 2,7-6,7 kW (redundant)
 * Außengerät, Innengerät, Zubehör bis 3,3-8,1 kW (single)
 * Außengerät, Innengerät, Zubehör bis 3,3-8,1 kW (redundant)
 * Außengerät, Innengerät, Zubehör bis 4,9-11,4 kW (single)
 * Außengerät, Innengerät, Zubehör bis 4,9-11,4 kW (redundant)
 * Außengerät, Innengerät, Zubehör bis 5,5-14 kW (single)
 * Außengerät, Innengerät, Zubehör bis 5,5-14 kW (redundant)
 * Außengerät, Innengerät, Zubehör bis 6,2-15 kW (single)
 * Außengerät, Innengerät, Zubehör bis 6,2-15 kW (redundant)
 * Tragrahmen zur Bodenmontage für bis zu 2 Klimaaußengeräte
 * Tragrahmen zur Bodenmontage für bis zu 4 Klimaaußengeräte
 * Wandkonsole für Klimaaußengerät bis 3,3-8,1 kW
 * Wandkonsole für Klimaaußengerät ab 4,9 bis 11,4kW
 * Rohrpaket 1,6-4,5 kW (25 Meter)
 * Rohrpaket 2,7-6,7 kW & 3,3 - 8,1 (25 Meter)
 * Rohrpaket ab 4,9 - 15 kW (25 Meter)

Kühlung mit Kaltwasserlösung möglich

Kühlung mit indirekter freier Kühlung möglich

Kühlung mit direkter freier Kühlung möglich



BRANDFRÜHESTERKENNUNG UND LÖSCHANLAGE

 * Brandfrühesterkennung und Löschanlage

 * 19“-Rack-Löschanlage sowie Brandfrühesterkennung für DC-ITSafe-Single
 * 19“-Rack-Löschanlage sowie Brandfrühesterkennung für DC-ITSafe-Duo
 * 19“-Rack-Löschanlage sowie Brandfrühesterkennung für DC-ITSafe-Triple
 * 19“-Rack-Löschanlage sowie Brandfrühesterkennung für DC-ITSafe-Quattro



BRANDFRÜHESTERKENNUNG

 * Brandfrühesterkennung

 * 19“-Rack- Brandfrühesterkennung für DC-ITSafe-Single
 * 19“-Rack- Brandfrühesterkennung für DC-ITSafe-Duo
 * 19“-Rack- Brandfrühesterkennung für DC-ITSafe-Triple
 * 19“-Rack- Brandfrühesterkennung für DC-ITSafe-Quattro



MONITORING

 * Monitoring

 * DCM Agent 32DI 2 PS inkl. Zubehör
 * DCM Erweiterungseinheit
 * Kombisensor Temperatur & Luftfeuchtigk. für DCM Detection/Agent
 * Feuchtigkeitssensor
 * Rauch/Feuermelder
 * Temperatursensor
 * Wasserleckagesensor



ELEKTROMANAGEMENT

 * Elektromanagement

 * Energieversorgung für ITSafe mit Unterverteilungen und Verkabelung zwischen
   ITSafe und Unterverteilungen, A-Pfad USV, B-Pfad Normalnetz
 * Energieversorgung für ITSafe mit Unterverteilungen und Verkabelung zwischen
   ITSafe und Unterverteilungen, A+B-Pfad über USV

USV ANLAGE (UNTERBRECHUNGSFREIE STROMVERSORGUNG)

 * USV Anlage (Unterbrechungsfreie Stromversorgung)

 * Interne USV-Anlage
   
   * 3 HE 19"-USV-Anlage 3600W, inkl. 9 Blöcke Batterien im Gehäuse,
     Autonomiezeit (bei 100% Nennleistung): ca. 57 Minuten, automatische
     Entgasungsfunktion
   
   * 3 HE 19"-USV-Anlage 6000W, inkl. 15 Blöcke Batterien im Gehäuse,
     Autonomiezeit (bei 100% Nennleistung): ca. 55 Minuten, automatische
     Entgasungsfunktion
   
   * 3 HE 19"-USV-Anlage 10000W, inkl. 20 Blöcke Batterien im Gehäuse,
     Autonomiezeit (bei 100% Nennleistung): ca. 41 Minuten, automatische
     Entgasungsfunktion
   
   * Zubehör: SNMP-Adapter Netman 204 je Anlage
   
   * Zubehör: PowerShield³ Kommunikations-Software je Anlage
   
   * Zubehör: Relaiskarte, Typ: MultiCom 384 je Anlage
   
   * Zubehör: Externer Slot-Adapter je Anlage, inkl. Halterung

 * Externe USV-Anlage
   
   * In verschiedenen Leistungsklassen auch außerhalb des DC IT Safes möglich

STECKDOSENLEISTEN / PDU-LEISTEN EINPHASIG

 * Steckdosenleisten / PDU-Leisten einphasig

 * PDU-Leisten von Basic-Varianten bis zu intelligenten Varianten mit Mess- und
   Schaltfunktionen gemäß Kundenanforderung


Thema auswählen DC IT Safe 56 HE DC IT Safe 62 HE
Thema auswählen
DC IT Safe 56 HE
DC IT Safe 62 HE
 * DC IT Safe 56 HE
 * DC IT Safe 62 HE


TECHNISCHE DETAILS

Breite 1.452 mm Höhe 2.185 mm Tiefe 1.470 mm (Weitere Größen auf Anfrage)
Profilrahmen (Zoll: mm) 19": 800 x 1200 HE Anzahl Horizontal 44 HE Anzahl
Vertikal 12 HE Anzahl Gesamt 56 Leergewicht (kg) ca. 1.100 Maximale
Belastbarkeit im 19"-Bereich (kg) 1.000 Klimatisierung Siehe
Ausstattungsoptionen Patentierte, innenliegende Click-Montagetechnik ✓
Selbstverriegelnde Automatik-Mehrfachverriegelung mit massiven Schwenkriegeln
und Dichtigkeitselementen ✓ Anzahl Weichschotts (optional Hartschott oder
Brandschutzhülsen) 4 Mögliche Positionierung Schotts in Seiten-, Boden- oder
Deckenelementen Mögliche Verschlussoptionen Siehe Ausstattungsoptionen


TECHNISCHE DETAILS

Breite 1.452 mm Höhe 2.425 mm Tiefe 1.470 mm (Weitere Größen auf Anfrage)
Profilrahmen (Zoll: mm) 19": 800 x 1200 HE Anzahl Horizontal 50 HE Anzahl
Vertikal 12 HE Anzahl Gesamt 62 Leergewicht (kg) ca. 1.100 Maximale
Belastbarkeit im 19"-Bereich (kg) 1.000 Klimatisierung siehe
Ausstattungsoptionen Patentierte, innenliegende Click-Montagetechnik ✓
Selbstverriegelnde Automatik-Mehrfachverriegelung mit massiven Schwenkriegeln
und Dichtigkeitselementen ✓ Anzahl Weichschotts (optional Hartschott oder
Brandschutzhülsen) 4 Mögliche Positionierung Schotts in Seiten-, Boden- oder
Deckenelementen Mögliche Verschlussoptionen Siehe Ausstattungsoptionen


DOWNLOADS

 * Steckbrief herunterladen
   
 * Maßblatt DC IT Safe Single 56HE
   168 KB
 * Maßblatt DC IT Safe Single 62HE
   168 KB
 * Maßblatt DC IT Safe Duo 56HE
   197 KB
 * Maßblatt DC IT Safe Duo 62HE
   198 KB
 * Maßblatt DC IT Safe Triple 56HE
   234 KB
 * Maßblatt DC IT Safe Triple 62HE
   234 KB
 * Maßblatt DC IT Safe Quattro 56HE
   282 KB
 * Maßblatt DC IT Safe Quattro 62HE
   371 KB
 * DC IT Safe Zubehörliste
   4 MB
 * Broschüre herunterladen
   7 MB


WAS KÖNNEN WIR FÜR SIE TUN?

Gemeinsam finden wir die passenden Produkte und Dienstleistungen für Ihre
individuellen Bedürfnisse. Um mehr zu erfahren, treten Sie gerne in persönlichen
Kontakt. Nutzen Sie dafür unser Kontaktformular oder rufen Sie uns einfach an.
Wir freuen uns auf Sie!

Kontakt aufnehmen Ansprechpartner finden


Switch language Deutsch Englisch (English)
Wir nutzen Cookies und andere Technologien.
Diese Website nutzt Cookies und vergleichbare Funktionen zur Verarbeitung von
Endgeräteinformationen und personenbezogenen Daten. Die Verarbeitung dient der
Einbindung von Inhalten, externen Diensten und Elementen Dritter, der
statistischen Analyse/Messung, der personalisierten Werbung sowie der Einbindung
sozialer Medien. Je nach Funktion werden dabei Daten an Dritte weitergegeben und
an Dritte in Ländern, in denen kein angemessenes Datenschutzniveau vorliegt und
von diesen verarbeitet wird, z. B. die USA. Ihre Einwilligung ist stets
freiwillig, für die Nutzung unserer Website nicht erforderlich und kann
jederzeit auf unserer Seite abgelehnt oder widerrufen werden.
Ablehnen Einstellungen Alles akzeptieren
Impressum Datenschutzhinweis
Made & Hosted in Germany by CCM19
Bitte wählen Sie zuzulassende Richtlinien aus
Technisch notwendig (2) ?
Hier sind alle technisch notwendigen Elemente zu finden, die für den Betrieb der
Website notwendig sind oder für die der Betreiber ein berechtigtes Interesse
nach Art. 6 Abs. 1 DSGVO hat.
Analyse / Statistiken (3) ?
Es werden Daten wie die Anzahl der Besucher und Seitenaufrufe erfasst und anonym
gespeichert.
Anzeigen / Ads (3) ?
Es werden Werbedienste von Drittanbietern genutzt. Wenn Sie hier zustimmen,
werden personenbezogene Daten an diese Anbieter übertragen.
Abbrechen Speichern Alle akzeptieren



+49 2741 9321-0
Mo-Fr 8.00-16.00h

Chat
Mo-Fr 8.00-16.00h

info@datacenter-group.com
Antwort werktags innerhalb von 24 Stunden

DC-Datacenter-Group GmbH
In der Aue 2
57584 Wallmenroth
Germany

 * Über uns
 * Karriere
 * Ansprechpartner
 * Kontakt
 * Newsletter

--------------------------------------------------------------------------------

 * Cookies
 * Terms & Conditions
 * Data Protection Policy
 * Hinweisgeberschutz
 * Impressum

 * 
 * 
 * 
 *