centiel.co.uk
Open in
urlscan Pro
134.213.158.79
Public Scan
Submitted URL: https://eurp.maillist-manage.eu/click.zc?m=1&mrd=168b58993b69735&od=3z719f951ffef26810b01d7d7228e56606&linkDgs=168b58993b6e343&r...
Effective URL: https://centiel.co.uk/cumuluspower-ups-three-phase-uninterruptible-power-supply/
Submission: On March 08 via api from CH — Scanned from NL
Effective URL: https://centiel.co.uk/cumuluspower-ups-three-phase-uninterruptible-power-supply/
Submission: On March 08 via api from CH — Scanned from NL
Form analysis
0 forms found in the DOMText Content
01420 82031 sales@centiel.co.uk * 30 YEARS OF EXPERIENCE * PRODUCTS * Modular Three-phase UPS * Stand-alone Three-phase UPS * Single-phase UPS * SERVICE & MAINTENANCE * Preventative Maintenance * PowerWave UPS Maintenance * Brochures * MEDIA * Press * Articles * Case Studies & White Papers * Videos * CAREERS * CONTACT * CENTIEL GLOBAL * Free UPS Health Check * CALL 01420 82031 Select Page * Free UPS Health Check * CALL 01420 82031 * 30 YEARS OF EXPERIENCE * PRODUCTS * Modular Three-phase UPS * Stand-alone Three-phase UPS * Single-phase UPS * SERVICE & MAINTENANCE * Preventative Maintenance * PowerWave UPS Maintenance * Brochures * MEDIA * Press * Articles * Case Studies & White Papers * Videos * CAREERS * CONTACT * CENTIEL GLOBAL CUMULUSPOWER™ 4th Generation True Modular UPS 10kW – 3.6MW Brochure CUMULUSPOWER™ CumulusPower is the latest generation of true modular UPS technology, offering the highest levels of availability and the lowest total cost of ownership (TCO). CumulusPower is designed with flexibility for future growth in mind. Its extensive portfolio of frame sizes range from 20 to 600kW and comprise of UPS modules with power of 10, 20, 25, 50 and 60 kW. Systems are parallelable up to 3.6MW. CumulusPower is ideally suited to protect critical loads within the data centre, finance and banking, and medical sectors. PreviousNext 12 HIGH AVAILABILITY FULL REDUNDANCY INDUSTRY LEADING VFI 97% EFFICIENCY BYPASS REDUNDANCY DISTRIBUTED ARCHITECTURE No single point of failure SMALL FOOTPRINT +0.51 MW/m² OUTSTANDING OVERLOAD CAPABILITY 124% continuous operation in overload MINIMIZED TOTAL COST OF OWNERSHIP ULTRA-SAFE ECO MODE 99.4% efficiency in Eco mode operation SWISS QUALITY ARCHITECTURE Thanks to our extensive failure analysis research and insights gathered from 25 years of field experience working with a large number of data centres and other critical environments, our power protection solutions have reached the highest levels of availability to reduce downtime risk, avoid costly errors, and increase energy efficiency. To respond to highest availability requirements i.e. to eliminate risks that may cause downtime of business-critical applications, CENTIEL has DISTRIBUTED ACTIVE-REDUNDANT ARCHITECTURE (DARA) The Distributed Active-Redundant Architecture of the CumulusPower™ product line is designed to respond to the highest availability requirements, through the implementation of the “democratic” majority load transfer decision-making in the event of a critical failure, and correct management of the load sharing to avoid crosscurrents between modules. The communication between the logic circuits of the modules is accomplished by means of a fault-tolerant dual communication BUS. In the event of a critical failure, every module will decide, by means of its developed a new series of fault-tolerant, Three-phase, true modular UPS-systems called CumulusPower™. Unlike traditional centralised parallel multi-module systems, the advanced CumulusPower™ technology combines a unique Intelligent Module Technology (IMT), with a fault-tolerant parallel architecture, called Distributed Active-Redundant Architecture (DARA), thereby fulfilling the highest availability and reliability requirements. logic circuit, whether the load should remain on the inverter or be transferred to the bypass. The load transfer will be conducted depending on the decision made by the majority of the modules. In order to avoid crosscurrents between the modules, a master-slave load sharing technique is adopted. The first module becomes the master which provides the load value to be shared by the rest of the modules (slaves). If the master fails, the next module will automatically become the leading master. DARA MODULAR ARCHITECTURE – Mains Bypass Line – Mains Rectifier Line – Data communications – DC Batteries – AC Output Line INTELLIGENT MODULE TECHNOLOGY (IMT) The CumulusPower™ modules are equipped with all hardware (power circuits) and all software (intelligence and monitoring) functions, making them fully independent and capable of safely isolating from the multi-module system whenever an internal fault occurs. If that should happen, the remaining modules will continue to provide protected power to the critical load without interruption. The integration of hardware and software in each module enables the elimination of all single points of failure which could compromise the power of the critical application. The core technology of the CumulusPower™ product family is based in 3 Intelligent Modules sizes that can be combined to create systems from 10kVA/kW to 3MW AVAILABILITY PROTECT YOUR CRITICAL APPLICATION, MINIMISE HUMAN ERROR. AVAILABILITY TO THE NEXT LEVEL 99.9999999% (9 NINES) The higher the Availability, the lower the downtime. By eliminating any single point of failure, adding active-redundant technology, preventing human error and reducing the time to maintain and repair, CumulusPower™ delivers an industry leading Availability of 9 nines to fulfil the needs of the most critical power applications. CumulusPower™, true modular UPS, takes downtime from seconds to the milliseconds level. Availability is formally defined as MTBF MTBF+MTTR CumulusPower™ maximizes the Mean Time Between Failure (MTBF) while minimizes the Mean Time To Repair with a series of future. MINIMISED MTTR Parallel system availability increases with the reduction of the Mean Time To Repair (MTTR). In-frame per-module bypass fuses minimise the time it takes to re-establish a system in an event fault. TRIPLE-MODE PARALLEL BUS Multi-frame connection is one of the advantages of horizontal scalability. Communication between frames and modules is critical, nevertheless, for some architectures, it is still a single point of failure. CumulusPower™ parallel communication is provided with a unique triple-mode parallel bus, that consists of three independent communication lines and three independent electronic circuits. With triple redundancy in the communication lines and electronic circuits the risk of disconnection or short-circuit on any of the communication lines is mitigated eliminating the single point of failure. FULL BYPASS REDUNDANCY Some UPS architectures still use centralised critical components like a Single Bypass Architecture (SBA). Centralised components in a parallel system represent single points of failure. Unlike the centralised architectures, Centiel’s modular UPS, CumulusPower™, is equipped with a Distributed Bypass Architecture (DBA), that brings full redundancy even in the bypass line, avoiding any system’ single point of failure. SAFE SMART BATTERY TEST CumulusPower™ battery tests are programmable and safe. Smart Battery Booster architecture allows the UPS to perform battery monitoring, tests and health status diagnosis without the need for mains disconnection. HOT-SWAPPABLE WITH MINIMISED HUMAN ERROR CumulusPower™ modules can be swapped without the need to switch over the load to bypass. Individual module parallel isolators disconnect from the system, minimising human error and increasing Availability. SYSTEM COSTS FLEXIBILITY: SAME CORE TECHNOLOGY DIFFERENT SOLUTIONS CumulusPower™ fits in a 19” (IM10/20) to provide the maximum flexibility to the final application. Centiel’s flexible solution approach can customize a frame solution to satisfy specific needs.” 1. REDUCED UP-FRONT INVESTMENT Compared to a standalone UPS solutions or centralised bypass architectures, Centiel’s scalable modular UPS have a lower total up-front investment cost, allowing you to grow your power protection capacity as your demand increases. 2. AVOID OVERSIZED DIESEL GENERATORS In the event of a mains failure our Unity Power Factor and Smart-Battery-Booster ensure that every switch over happens smoothly, minimising in-rush current, avoiding generator destabilisation and eliminating the need for generator oversizing. 3. ELIMINATE AD-ON EXTERNAL COMPONENTS Back-feed protection in every module and maintenance bypass, bypass fuses and battery DC breakers within the UPS frame eliminate the need for external components connections, reducing Total Cost of Ownership. 4. SAVE ON BATTERIES Batteries represent a substantial part of a project cost structure. With CumulusPower™ you have the flexibility to select the number and type of battery blocks that best suit your application. Letting you decide on a case by case basis the best way to optimise total system cost. 5. HIGH EFFICIENCY MEANS LESS HEAT CumulusPower™ industry-leading VFI 97% efficiency and its flat efficiency curve, contribute to low energy losses and heat dissipation, reducing the size and cost of cooling systems. 6. HIGH BATTERY CHARGING CURRENT CAPABILITY The innovative modular design of CumulusPower allows a higher charge current capability whilst protecting the batteries at all times. This allows for faster, safer charging. TOTAL COST OF OWNERSHIP MAXIMUM EFFICIENCY MANAGEMENT (MEM) Use energy only when it is needed. Cumuluspower™ incorporates a user enabled intelligent MEM that only uses as many modules as necessary to match the load demand. MEM constantly looks for the optimal energy efficiency point. If the load demand decreases, MEM calculates that a reduced number of modules could support the load whilst still maintaining redundancy. The surplus modules enter an “active-sleep” mode to optimise the overall energy consumption. If the load increases, and additional modules are required to support the higher load, “active-sleep” modules are instantaneously reactivated to support the load. OPTIMISE VALUABLE SPACE (MINIMIZED FOOTPRINT) With only 0.29m² for 10/20 kW and 0.44m² for 30/40/60 kW, the PremiumTower ™ optimises valuable floor space, eliminates the cost of an additional battery cabinet, and simplifies the installation. PROVIDE INDUSTRY-LEADING AVAILABILITY The higher the Availability, the shorter the downtime. Eliminating single points of failure, adding active-redundant technology, helping to prevent human error and reducing the time to maintain and repair allows Cumuluspower™ to deliver an industry leading Availability of 9 nines to fulfill the needs of the most critical power applications. Cumuluspower™ reduces downtime from seconds to the milliseconds. Availability is formally defined as MTBF MTBF+MTTR The advanced Cumuluspower™ design maximises the Mean Time Between Failure (MTBF) whilst minimising the Mean Time To Repair. MINIMISED LIFE-TIME MAINTENANCE COST Preventative maintenance is important to maximize availability. Centiel develop products to reduce the time and costs associated with preventative maintenance and minimise the number of components that require routine replacement. The innovative design of CumulusPower also simplifies these replacements, reducing the time and cost involved. PROVIDE OUTSTANDING OVERLOAD CAPABILITY (OUTSTANDING OVERLOAD CAPABILITY) With continuous operation at 124% overload, mission critical applications will be safe in the event of unexpected load demands. REDUCE YOUR ENERGY BILL High efficiency means less heat dissipation, and therefore less energy wasted. Cumuluspower™ reduces the energy consumption of the power protection equipment and the associated cooling systems. USE ENERGY ONLY WHEN IT IS NEEDED WITH CUMULUSPOWER™ ACTIVE-SLEEP MODE. SERVICEABILITY KEEPING A HEALTHY UPS SHOULD BE SAFE AND EASY: SERVICEABILITY STATE OF THE ART SERVICE TOOLS CumulusPower™ service tools allow technicians, to connect, download events, verify configuration and change parameters of the UPS with a simple tap of the screen. The mobile and tablet app provides a full toolbox to read and interpret the health of the system. SAFE POWER-UPGRADES: REDUCE HUMAN ERROR Power capacity upgrades and module substitution are two critical operations where human error can compromise the system load. To eliminate this risk every module in a CumulusPower™ frame can be fully isolated from the parallel system, thanks to the parallel isolator. This isolator allows technicians to perform a full module test and parameters configuration in a running system without the need for load disconnection or for your system to switch to bypass. This feature eliminates the possibility of connecting a faulty module to the parallel system which could compromise the connected load. BACK-FEED PROTECTION: INCREASED SAFETY AND REDUCED SYSTEM COST Embedded into the module as standard is back-feed protection which increases service personnel safety, reduces total system cost and avoids external components. PER-MODULE 3” GRAPHICAL USER INTERFACE With CumulusPower™ graphical user interface it is easy to read measurements, parameters, messages, alarm and any parameter of the UPS. ADVANCED PERFORMANCE UNITY POWER FACTOR (KVA = KW) CumulusPower™ provides unity power factor output which avoids the need for system oversizing. HIGH EFFICIENCY 97% (VFI) With a best in class efficiency of 97% in double conversion mode (VFI), CumulusPower™ provides the lowest Total Cost of Ownership. OUTSTANDING OVERLOAD CAPABILITY With a 124% continuous operation in overload condition, mission critical applications will be safe in the event of unexpected load demands. EXCEPTIONAL SHORT CIRCUIT CAPABILITY With a Short Circuit Capability of 3 times nominal current (3 x In), CumulusPower™ is able to clear output circuit protection in milliseconds. CUMULUSPOWER™ FAULT TOLERANT THREE-PHASE UPS FROM THE DESIGNERS OF THE 1ST THREE-PHASE TRANSFORMERLESS UPS AND THE 1ST, 2ND AND 3RD GENERATION MODULAR UPS, COMES THE 4TH GENERATION. CUMULUSPOWER™ FAULT TOLERANT THREE-PHASE UPS FROM THE DESIGNERS OF THE 1ST THREE-PHASE TRANSFORMERLESS UPS AND THE 1ST, 2ND AND 3RD GENERATION MODULAR UPS, COMES THE 4TH GENERATION. PRODUCT LINE INTELLIGENT MODULES IM10 IM20 IM25 10 kVA/kW 20 kVA/kW 25 kVA/kW CP050-I080-A0 CP050-I080-A0 CP050-I080-A0 CP050-I080-A1 CP050-I080-A1 CP050-I080-A1 CP100-E-A1 CP100-E-A1 CP100-E-A1 CP100-I320-B0 CP100-I320-B0 CP100-I320-B0 CP150-E-A0 CP150-E-A0 CP150-E-A0 CP250-E-B0 CP250-E-B0 CP250-E-B0 IM50 IM60 50 kVA/kW 60 kVA/kW CP300-E-B0 CP300-E-B0 CP600-E-D0 CP600-E-D0 TECHNICAL DATA SHEET Download BESPOKE APPLICATION? Contact us Arrow HOT TOPICS * 99.9999999% System Availability * Modular Uninterruptible Power Supplies * Distributed Active Redundant Architecture * Lithium-ion * Uninterruptible Power Supply Maintenance Terms and Conditions | Privacy Policy | Cookie Policy © 2022 Centiel UK Ltd. All rights reserved | Company Registration number 5544950 | Site by Diagonal 01420 82031 sales@centiel.co.uk Follow us on Twitter Sign up to our mailing list Follow us on LinkedIn