CALCULATE YOUR N2 PRODUCT

Use Evonik’s SEPURAN® N2 calculator to learn how much nitrogen you can make.
Estimate the number and type of membranes you need by inputting the nitrogen
flow, temperature, nitrogen purity and pressure.


ENTER YOUR PARAMETERS HERE

OutletInlet
Nitrogen quantity required Nm3/hSm3/h(20°C, 1atm)
m3/hNL/minNL/hkg/hMMscfdscfmscfh# products
Nitrogen purity required in %
9599.797
Temperature in ˚C˚F
107025
Pressure in bargpsigbarapsiaMpaGkPaG
5.3259
Calculate


OUR PRODUCT RANGE

6" long system

6" system

4" system

4" short module

6" selective system

2" short Alu

2" short PVC

2" long Alu

2" long PVC



THE SEPURAN® N2 6“ LONG MEMBRANE CARTRIDGE SYSTEM



SEPURAN® N2 6 "systems can operate up to 16 barg / 232 psig at temperatures up
to 70 ° C.

The SEPURAN® N2 6“ product is available as cartridge system in SS316. The
product comes with NPT and BSPP ports and is available certified as PED, ASME,
CRN & Selo.

Product information

6" long system


THE SEPURAN® N2 6“ LONG MEMBRANE CARTRIDGE SYSTEM



SEPURAN® N2 6 "systems can operate up to 16 barg / 232 psig at temperatures up
to 70 ° C.

The SEPURAN® N2 6“ product is available as cartridge system in SS316. The
product comes with NPT and BSPP ports and is available certified as PED, ASME,
CRN & Selo.

Product information

6" system


THE SEPURAN® N2 6“ MEMBRANE CARTRIDGE SYSTEM



The SEPURAN® N2 6“ product is available as cartridge system in SS316. The
product comes with NPT and BSPP ports and is available certified as PED, ASME,
CRN & Selo.

SEPURAN® N2 6” systems can be operated up to 25 barg / 362 psig with
temperatures up to 70 °C / 158F.

Product information

4" system


THE SEPURAN® N2 4“ MEMBRANE CARTRIDGE SYSTEM



The SEPURAN® N2 4“ product is available as cartridge system in SS316. The
product comes with either NPT and BSPP ports.

SEPURAN® N2 4” systems can be operated up to 16 barg / 232 psig with
temperatures up to 70 °C / 158F.

Product information

4" short module


THE SEPURAN® N2 4“ MEMBRANE MODULES



The SEPURAN® N2 4“ product is available as cast in place module in SS304. The
product comes with NPT ports.

SEPURAN® N2 4" modules can be operated up to 16 barg / 232 psig with
temperatures up to 70 °C / 158F.

Product information

6" selective system


THE SEPURAN® N2 6“ SELECTIVE SYSTEM



The SEPURAN® N2 6“ product is available as cartridge system in SS316. The
product comes with NPT and BSPP ports and is available certified as PED, ASME,
CRN & Selo.

SEPURAN® N2 6” selective systems can be operated up to 25 barg / 362 psig with
temperatures up to 70 °C / 158F

Product information

2" short Alu


THE SEPURAN® N2 2“ SHORT ALU MEMBRANE MODULES



The SEPURAN® N2 2“ Short ALU product is available as cast in place module in
aluminum. The product comes with NPT ports.

SEPURAN® N2 2” Short ALU modules can be operated up to 12 bara / 175 psia with
temperatures up to 70°C / 158°F.

Product information

2" short PVC


THE SEPURAN® N2 2“ SHORT PVC MEMBRANE MODULES



The SEPURAN® N2 2“ Short PVC product is available as cast in place module in
PVC. The product comes with NPT ports.

SEPURAN® N2 2” Short PVC modules can be operated up to 10 bara / 145 psia with
temperatures up to 40°C / 104°F.

Product information

2" long Alu


THE SEPURAN® N2 2“ LONG ALU MEMBRANE MODULES



The SEPURAN® N2 2“ Long ALU product is available as cast in place module in
aluminum. The product comes with NPT ports.

SEPURAN® N2 2” Long ALU modules can be operated up to 12 bara / 175 psia with
temperatures up to 70°C / 158°F.

Product information

2" long PVC


THE SEPURAN® N2 2“ PVC ALU MEMBRANE MODULES



The SEPURAN® N2 2“ Long PVC product is available as cast in place module in PVC.
The product comes with NPT ports.

SEPURAN® N2 2” Long PVC modules can be operated up to 10 bara / 145 psia with
temperatures up to 40°C / 104°F.

Product information

This information and any recommendations, technical or otherwise, are presented
in good faith and believed to be correct as of the date prepared. Recipients of
this information and recommendations must make their own determination as to its
suitability for their purposes. In no event shall Evonik assume liability for
damages or losses of any kind or nature that result from the use of or reliance
upon this information and recommendations. EVONIK EXPRESSLY DISCLAIMS ANY
REPRESENTATIONS AND WARRANTIES OF ANY KIND, WHETHER EXPRESS OR IMPLIED, AS TO
THE ACCURACY, COMPLETENESS, NON-INFRINGEMENT, MERCHANTABILITY AND/OR FITNESS FOR
A PARTICULAR PURPOSE (EVEN IF EVONIK IS AWARE OF SUCH PURPOSE) WITH RESPECT TO
ANY INFORMATION AND RECOMMENDATIONS PROVIDED. Reference to any trade names used
by other companies is neither a recommendation nor an endorsement of the
corresponding product, and does not imply that similar products could not be
used. Evonik reserves the right to make any changes to the information and/or
recommendations at any time, without prior or subsequent notice.

Contact
Sitemap
Company information
Legal notice
Data protection