Heat metering for vertical distribution – 1

Today, the solution of apartment heat metering with vertical layout rests on the
price of the issue. Converting a vertical layout to a horizontal one is
expensive and not all tenants will agree. The costs are about $1630 or 29320 lei
per flat. However, there is a non-obvious solution – to take into account the
heat from the risers.

If metering is placed on risers, for example, for 5 floors, this will be a total
heat metering for 5 apartments. In this case, the savings are already tangible.
In addition, this is the control of the operation of the general house meter,
control of losses inside the house, the identification of “clogged” risers,
installed additional sections, heating of balconies, as well as control of
unauthorized connection to the network of leased premises.

 

This works, since the entrance, and even more so the riser is more mobile, there
is no need to negotiate with all the residents of the house at once. And the
residents of the entrance often decide themselves to install an intercom,
replace the door, and make repairs. It is even easier to agree on the riser:
only 5-10 apartments – for example, to make the facade insulation to reduce
loss.

 

Thus, 10-20 groups of apartments appear in the house. Several groups will
definitely get ahead and cut their heating bills by more than half. This
information will be available to all residents on the website www.djv-com.org,
in addition, this comparative information can be published in each entrance,
then the rest of the entrances will also be tightened. There is no guarantee
that everyone will be the same, but as a result, heating bills around the house
will decrease by 30 – 40%.

 

There is one more feature, for example, the tenant is not going to save on heat,
but his grandmother lives below him, for whom it is VERY important to save,
since her pension will not be enough to pay for the heat, then the tenant will
also start saving out of solidarity.

 

Even if one family member takes on the task of saving, that will be enough. It
can also be a child who decides to check in practice what will change in
consumption if, when leaving for school, cover the radiators with a blanket or a
towel.



From the calculation it turns out for 1/2/3 room apartment (excluding labor
costs) it is 444/666/888 lei, for a five-storey building it will be
888/1332/1776 lei, respectively. The difference in price compared to the
conversion to horizontal wiring of 29,320 lei per apartment is very significant.

 

The same distribution of payment for heat is incorrect for many reasons:

– different thermal insulation of apartments, someone is watching this, and
someone is letting heat to the wind.

 

– the consumer does not have the opportunity to save payment for heat, since if
he saves it, he will pay no less from this. Is it worth freezing for this?

 

– there is no trace left of the initial projects of houses – some have
three-section batteries, some already have 20-section batteries. It is no secret
that some residents heat not only apartments, but also extensions and loggias.

 

– due to numerous repairs of the heating system, the diameters of the risers can
differ significantly from riser to riser, respectively, the heat selection on
different risers is different.

 

– it is no secret that the volume of the coolant passing through different
risers is regulated in different ways, this is due both to the section of the
riser pipe, which changes its section over time, or may simply be clogged, and
the ability to regulate the flow rate using valves, in order to supply more heat
to one riser and less heat to the other.

 

– if the apartment is closed and no one lives in it, there is no way to reduce
heat consumption, and therefore payment for it, which is a violation of consumer
rights.

 

– if the owner of the apartment uses other sources of heat energy – an electric
fireplace, heated floors, which means he consumes less heat from the heating
system, this does not reduce the heat energy bill.

 