www.ifm.com
Open in
urlscan Pro
2a02:26f0:3500:89a::1e45
Public Scan
Submitted URL: https://click.mail.ifm.com/?qs=473f8e7fd8b65b8184a5569041df6fa01c9613f96a4c769e7192c9f9134a6756884ec7fa0c32ce99b595ff68b019...
Effective URL: https://www.ifm.com/gb/en/shared/productnews/2024/hygienic-flow-sensor-with-io-link?utm_source=sfmc&utm_term=&utm_co...
Submission Tags: falconsandbox
Submission: On November 13 via api from US — Scanned from GB
Effective URL: https://www.ifm.com/gb/en/shared/productnews/2024/hygienic-flow-sensor-with-io-link?utm_source=sfmc&utm_term=&utm_co...
Submission Tags: falconsandbox
Submission: On November 13 via api from US — Scanned from GB
Form analysis
2 forms found in the DOM/gb/en/search
<form id="form-search-bar" action="/gb/en/search" class="ifm-search__form" role="search" data-test="search-form">
<div class="ifm-search__input-wrapper"><input id="search-bar__input" class="ifm-search__input normalize" name="query" type="search" data-cycle-focus-search-bar="" required="" placeholder="Enter search term." spellcheck="false" autocomplete="off"
autocorrect="off" accesskey="f" data-test="search-input" tabindex="0"><button aria-label="Clear search" data-clear-button="" class="ifm-search__clear hover-link-2 normalize" hidden="" type="reset" data-test="reset-button" tabindex="1"><svg
viewBox="0 0 24 24" class="icon icon-svg icon-svg--medium" aria-hidden="true">
<use href="#close-circle"></use>
</svg></button></div><button type="submit" class="ifm-search__submit normalize ifm-button" data-test="search-button" tabindex="0"><svg viewBox="0 0 24 24" class="inline-icon icon-svg--medium ifm-button__icon" aria-hidden="true">
<use href="#search" class=""></use>
</svg><span class="ifm-button__label hide-xs">Search</span></button><input type="hidden" name="searchSessionId" value="1731497583810.yece8rt">
</form>
POST /gb/en/login.user
<form method="post" action="/gb/en/login.user" class="ifm-login__form" data-matomo-name="Login"><input type="hidden" name="_csrf" value="77e342e5-7ad2-491a-80dd-4dbec975b686"><input type="hidden" name="targeturl"
value="https://www.ifm.com/gb/en/secure/my-ifm/"><input type="hidden" name="newFav"><input type="hidden" name="quickLogin" value="true">
<fieldset class="ifm-fieldset">
<legend class="ifm-fieldset__headline h3 sr-only">Registration data</legend><!----><label class="ifm-input-label"><span class="ifm-input-label__text">E-mail address</span><input class="ifm-input pristine" name="username" type="email"
autocomplete="email" required="" maxlength="100"></label><label class="ifm-input-label"><span class="ifm-input-label__text">Password</span><input class="ifm-input pristine" name="password" type="password" autocomplete="current-password"
required="" maxlength="100"></label><label class="ifm-checkbox ifm-input-label ifm-input-label--inline ifm-checkbox--selected"><input class="ifm-checkbox__input pristine" type="checkbox" name="rememberMe" value="true"><svg viewBox="0 0 24 24"
class="ifm-checkbox__icon" aria-hidden="true">
<rect x="1" y="1" width="22" height="22" class="ifm-checkbox__icon-box"></rect>
<path d="M5 12l5 5L20 7" class="ifm-checkbox__icon-check" stroke-width="2"></path>
</svg><span class="ifm-checkbox__text">Keep me logged in</span><!----></label>
</fieldset>
<div class="ifm-login__submit-wrapper"><a href="/gb/en/register?quickLogin=true&register=true" class="ifm-login__register-button ifm-button ifm-button--secondary">Register</a><button type="submit"
class="ifm-login__submit-button normalize ifm-button pristine">Log in</button><!----></div>
</form>
Text Content
Search All results Service hotline0208 213 2222 GB United Kingdom English Change country Registration dataE-mail addressPasswordKeep me logged in RegisterLog in -------------------------------------------------------------------------------- Forgot your password? * Products * Industries * IIoT & Solutions * Service * Company ˙ * Product news * Sensors * Hygienic flow meter with IO-Link * Condition monitoring * Image processing / Identification * Safety technology * Industrial communication * IO-Link * Systems for mobile machines * Display / Operate / Illuminate * IIoT solutions * Connection technology * Power supply * Accessories HYGIENIC FLOW METER WITH IO-LINK NO MORE BLIND SPOTS IN THE DIGITAL PROCESS The SM Foodmag magnetic-inductive flow sensor takes the flow measurement of liquid and creamy foods to a new level. Equipped with IO-Link, the sensor is the first of its kind to enable digital data transmission from the process, eliminating the last blind spot in the digitalised, transparent production process. On site, the display itself and the all-round visible status LED provide information on the current status. MEASURES WHAT MATTERS The sensor detects the current flow rate, total volume and flow direction, as well as the presence of the medium (often referred to as empty pipe detection). It also transmits conductivity and temperature to the control system and IT level. This can reduce the need for additional measuring points in the system. CONVENIENCE, CLARITY, SAFETY The integration of the SM Foodmag almost takes care of itself. Combined with our patented cables, the standard M12 connection ensures a fast, waterproof and error-free connection to the data infrastructure. Standard installation dimensions and a flexible choice of seals and process adapters make it easy to integrate into existing systems. The app-based menu structure and guided installation make parameter setting a breeze. Locally and digitally, the SM Foodmag ensures maximum visibility inside the pipe – for greater process reliability. THE GAME CHANGER * Magnetic-inductive flow meter completes the portfolio for the food industry * Reduces the need for measuring points by providing flow rate, total volume, temperature and conductivity * Easy to set up thanks to app-based menu and guided installation Current factsheet * PDF Download (441 KB) INTENSIVE TESTING FOR LONG-LASTING QUALITY Extensive internal and external tests ensure from the outset that the SM Foodmag can withstand the extreme conditions of day-to-day processing in the food industry - in the long term. The temperature shock test puts the sensor’s accuracy to the test when exposed to large temperature fluctuations. These occur during the pasteurisation process, for example, when milk or highly acidic products are heated to between 72 °C and 95 °C and then rapidly cooled down. This process ensures the shelf life of the products. Even after 1,000 hours of continuous stress due to rapid temperature changes from sub-zero to the high double-digit range, the measurement result must still be within the specified accuracy band. Pumps and valves are required to move the media from the tank to the downstream processing steps. Pumps provide continuous vibration and quick-opening valves for pressure peaks. The pressure peak test simulates the rapid pressure surges by applying a pressure load that deliberately exceeds the pressure rating specified in the data sheet. After one million cycles, the SM Foodmag is tested for leakage. Shock and vibration along the X, Y and Z axes are also intensively simulated over several days to ensure that external influences do not have a significant impact on the performance of the devices. In the condensation test, a cold medium is passed through the pipe system and sensor - while the ambient temperature is warm. The SM Foodmag is exposed to high humidity and the resulting condensation for several weeks and in different installation positions to ensure that no moisture can penetrate the device. BUILD THE RIGHT SOLUTION FOR YOU NOW We provide you with our innovative Solution Builder so that you can benefit quickly and easily from the precision of our flow sensors for the food industry. Define your requirements - and we will put together your product solution. Sounds good? Then why not give it a try right away? Start now PRODUCTS Units of measurement: SI, EU SMF320 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,060.70 Your price:Please log in Save for laterCompare SMF420 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,126.40 Your price:Please log in Save for laterCompare SMF520 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,278.50 Your price:Please log in Save for laterCompare SMF620 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,420.30 Your price:Please log in Save for laterCompare SMF720 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,766.00 Your price:Please log in Save for laterCompare Units of measurement: SI, EU, imperial SMF321 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,060.70 Your price:Please log in Save for laterCompare SMF421 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,126.40 Your price:Please log in Save for laterCompare SMF521 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,278.50 Your price:Please log in Save for laterCompare SMF621 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,420.30 Your price:Please log in Save for laterCompare SMF721 Magnetic-inductive flow meter Magnetic-inductive flow meter; PNP/NPN; pulse signal; totaliser switching signal List price:£2,766.00 Your price:Please log in Save for laterCompare ARE YOU READY FOR A SMART IO-LINK MANAGEMENT? Here you can find information about our configuration software moneo configure free THE SU PURESONIC ULTRASONIC FLOW SENSOR Accurate flow measurement of water and ultrapure water FAST-RESPONSE, PRECISE FLOW SENSOR Reliable process quality through continuous monitoring of the conformal temperature control Sustainability Terms and conditions Warranty policy Privacy policy Data Subject Access Request (DSAR) policy Responsible Disclosure Cookies ifm electronic ltd. efector House Kingsway Business Park Oldfield Road Hampton Middlesex TW12 2HD Great Britain phone 020 8213-2222 email enquiry.gb@ifm.com United Kingdom(GB)Trade partners © ifm electronic gmbh 2024