www.dropbox.com
Open in
urlscan Pro
2620:100:6022:18::a27d:4212
Public Scan
URL:
https://www.dropbox.com/s/4980jltu5221mb0/O%26M%20Manuals.pdf?dl=0
Submission: On May 08 via manual from US — Scanned from DE
Submission: On May 08 via manual from US — Scanned from DE
Form analysis
0 forms found in the DOMText Content
Herunterladen Kopie auf Dropbox speichern Speichern als … AnmeldenRegistrieren 1. 1 2. 2 3. 3 4. 4 5. 5 6. 6 7. 7 8. 8 9. 9 10. 10 11. 11 12. 12 13. 13 14. 14 15. 15 16. 16 17. 17 18. 18 1. Operations and Maintenance Manuals2050 Versailles RdLexington, Kentucky 40504 2. Insert your text hereTABLE OF CONTENTSO1 -Operation and Maintenance Manuals014 Model F1FR 56 Quick Response Sprinklers.......................................5-1225-2011-PDF..............................................................................................................14-143Flex Drop...................................................................................................................145-150test papers phase 1............................................................................................152-155test papers phase 2............................................................................................157-160O2 -Operation and Maintenance Manuals08 11 00 Steel Doors and Frames O&M................................................162-16408 21 20 Flush Wood Veneer Doors O&M...........................................166-16608 71 00 Door Hardware O&M..................................................................168-17010 26 00 Wall Protection O&M....................................................................172-172MX-3051_20221201_123402........................................................................174-197MX-3051_20221201_125328........................................................................199-202MX-3051_20221201_125603........................................................................204-205O3 -Operation and Maintenance Manuals 3. Insert your text hereWood Concept O&M..........................................................................................207-207O4 -Operation and Maintenance ManualsO and M.....................................................................................................................209-211 4. 014 Model F1FR 56 Quick Response SprinklersO1 - Operation and Maintenance ManualsPage 4 of 211TABLE OF CONTENTS 5. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523Model F1FR SeriesQuick ResponseGlass Bulb SprinklersBulletin 014 Rev. M Bulletin 014 Rev. M Model F1FR56 Sprinkler TypesStandard Spray UprightStandard Spray PendentConventional Upright/PendentVertical SidewallHorizontal SidewallModel F1FR56 Recessed Sprinkler TypesStandard Spray PendentHorizontal SidewallModel F1FR56 Concealed Sprinkler TypesStandard Spray PendentModel F1FR42, F1FRXLH & F1FR28 Sprinkler TypesStandard Spray UprightStandard Spray PendentModel F1FR40 Sprinkler TypesStandard Spray PendentModel F1FR42, F1FR40, F1FRXLH & F1FR28 Recessed Sprinkler TypesStandard Spray PendentModel F1FR56LL & F1FR42LL NSF Certifi ed Low Lead Sprinkler TypesStandard Spray Pendent with less than 0.25% Lead ContentListing & ApprovalsThe following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin-kler.1. Underwriters Laboratories Inc. and Certified for Canada (cULus).2. FM Approvals (FM)3. Loss Prevention Certification Board (LPCB)4. Vertrauen durch Sicherheit (VdS)5. NSF Certified to NSF/ANSi Standard 61 Annex G (NSF)6. EC Certificate: 0786-CPD-40239 (RA1414), 0786-CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC)UL Listing CategorySprinklers, Automatic & Open (VNIV)Quick Response SprinklerPendent ConventionalRecessedPendent/F1/F2UprightVertical Sidewall Horizontal SidewallRecessedHorizontal SidewallRecessedPendent/FPConcealedPendent XLH Upright XLH PendentXLH RecessedPendent F1/F2XLH RecessedPendent FPProduct DescriptionReliable Model F1FR series sprinklers are quick-response automatic sprin-klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan-dard Spray sprinklers, with the excep-tion of the Model F1FR56 Conventional sprinkler which is an Old-style/Conven-tional sprinkler.The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat-ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating.The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man-ufactured glass capsule. This glass bulb is specially con-structed to provide fast thermal response.Powered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf | 5 of 211TABLE OF CONTENTS 6. 2.At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq-uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib-ute the discharging water.Model F1FR Series sprinklers provide a wide range of op-tions where quick-response, glass bulb sprinklers are used:• Pendent, recessed pendent, upright, horizontal side-wall, and vertical sidewall defl ectors• K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric)• Flush, recessed, and concealed installationsSee the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations.Model F1FR Recessed Pendent and Recessed Horizon-tal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Re-cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment.Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov-er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In-stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap-proved cover plate options.ApplicationModel F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav-ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin.Installation Glass bulb sprinklers have orange bulb protectors or pro-tective caps to minimize bulb damage during shipping, han-dling and installation. Reliable sprinkler installation wrench-es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin-kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul-nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors.Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler.Recessed SprinklersModel F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe-cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutch-eon will void all approvals and negate all warranties.Concealed SprinklersModel F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in-stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage-ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above.Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov-ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com-pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above.Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals.Powered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf | 6 of 211TABLE OF CONTENTS 7. 3.Design and Installation InformationModelNominalK-factorNominalOrifi ceDiameterDefl ector/OrientationNominal Sprinkler HeightInstallation WrenchSINListingsandApprovalsApproval NotesUS Metric inches mm inches mmF1FR282.8 40 3/8 10Pendent 2.25 57 D RA1411 cULus 2Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2Upright 2.25 57 D RA1421 cULus 1,2F1FR404.0 57 3/8 10Pendent 2.25 57 D RA1418 VdSRecessed Pendent 2.25 57 GFR2 RA1418 VdSF1FR424.2 60 7/16 10Pendent 2.25 57 D RA1413 cULus 2Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2Upright 2.25 57 D RA1423 cULus 1,2F1FR42LL4.2 60 7/16 10Pendent 2.25 57 D RA1410 cULus, NSFRecessed Pendent 2.25 57 GFR2 RA1410 cULus, NSFF1FRXLH(F1FR42 with Pintle)4.2 60 7/16 10Pendent 2.25 57 D RA1413 cULus 2Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2Upright 2.25 57 D RA1423 cULus 1,2F1FR565.6 80 1/2 15Pendent 2.25 57 D RA1414cULus, FM, LPCB, VdS, EC1,2,3,4Recessed Pendent 2.25 57 GFR2 RA1414cULus, FM, LPCB, VdS, EC1,2,3,4Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6Upright 2.25 57 D RA1425cULus, FM, LPCB, VdS, EC1,2,3,4"Conventional(Pendent or Upright)"2.25 57 D RA1475 LPCB, VdS, EC 4F1FR56LL5.6 80 1/2 15Pendent 2.25 57 D RA1415 cULus, NSF 1Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSFConcealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6F1FR565.6 80 1/2 15Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7Recessed Horizontal Sidewall2.63 67 GFR2 RA1435 cULus, FM 8F1FR565.6 80 1/2 15Vertical Sidewall (Pendent or Upright)2.25 57 D RA1485cULus, FM, LPCB1,2,3,9(1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating.(3) Available with FM approved Polyester coating in black or white.(4) Available with LPCB and VdS approved Polyester coating.(5) VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin-klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment.(7) cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori-zontal Sidewall sprinkler is for Light Hazard occupancies only.(8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil-ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only.Technical Data:Sensitivity: Quick-responseThread Size: 1/2-inch NPT standard; ISO 7-R1/2 optionalMaximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar)Powered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf | 7 of 211TABLE OF CONTENTS 8. 4.Listed and Approved Temperature Ratings ModelDefl ector/OrientationOrdinary Temp.Classifi cation100°F (38°C) Max. Ambient Temp.Intermediate Temp.Classifi cation150°F (65°C) Max. Ambient Temp.High Temp.Classifi cation225°F (107°C) Max.Ambient Temp.135°F (57°C) Temp. Rating155°F (68°C) Temp. Rating175°F (79°C) Temp. Rating200°F (93°C) Temp. Rating286°F (141°C) Temp. RatingOrange Bulb Red Bulb Yellow Bulb Green Bulb Blue BulbF1FR28Pendent cULusRecessed Pendent cULus --Upright cULusF1FR40Pendent VdSRecessed Pendent VdS --F1FR42Pendent cULusRecessed Pendent cULus --Upright cULusF1FR42LLPendent -- cULus, NSF --Recessed Pendent -- cULus, NSF --F1FRXLHPendent cULusRecessed Pendent cULus --Upright cULusF1FR56Pendent cULus, FM, LPCB, VdS, ECRecessed Pendent cULus, FM, LPCB, VdS, EC --Concealed Pendent* cULus cULus,VdS,EC cULus --Upright cULus, FM, LPCB, VdS, EC“Conventional(Pendent or Upright)”LPCB, VdS, ECF1FR56LLPendent -- cULus, NSF --Recessed Pendent -- cULus, NSF --Concealed Pendent* -- cULus, NSF --F1FR56Horizontal Sidewall cULus, FMRecessed Horizontal SidewallcULus, FM --F1FR56Vertical Sidewall (Pen-dent or Upright)cULus, FM, LPCB* Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate.Recessed Escutcheon Data ModelDefl ector/OrientationListed and Approved Recessed EscutcheonsSINModel F1(Fig. 1 & 3)3/4-inch (19mm) adjustmentModel F2(Fig. 1 & 3)1/2-inch (12.7mm) adjustmentModel FP(Fig. 2)1/2-inch (12.7mm) adjustmentF1FR28Recessed Pendent cULus cULus cULus RA1411F1FR40Recessed Pendent VdS VdS VdS RA1418F1FR42Recessed Pendent cULus cULus cULus RA1413F1FR42LLRecessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410F1FR42XLHRecessed Pendent cULus cULus cULus RA1413F1FR56Recessed PendentcULus, LPCB, VdS, ECcULus, FM, LPCB, VdS, ECcULus, VdS, EC RA1414F1FR56LLRecessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415F1FR56Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435Powered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf | 8 of 211TABLE OF CONTENTS 9. 5.Fig. 1Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheonFig. 2Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheonPowered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf | 9 of 211TABLE OF CONTENTS 10. 6.Fig. 3Model F1FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheonFig. 4Model F1FR56/F1FR56LL Concealed Pendent sprinkler with standard depth1/2-inch (12.7mm) adjustment - Model CCP cover platePowered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf | 10 of 211TABLE OF CONTENTS 11. 7.Fig. 5 - Model F1FR56/F1FR56LL Concealed Pendent sprinkler with low profile5/16-inch (8.0mm) adjustment - Model CCP cover plateMaintenance The Model F1FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard FinishesSprinkler Escutcheon Cover plate(1)Bronze Brass ChromeChrome Plated Chrome WhitePolyester PlatedCoated (4)(5)(6)White PaintedSpecial Application FinishesSprinkler Escutcheon Cover plate(1)Electroless Nickel PTFE(7)Electroless Nickel PTFE Bright BrassBright Brass(3)Bright Brass Black PlatingBlack Plated Black Plated Black PaintBlack Paint(2)(6)Black Paint Off WhiteOff White(2)(6) Off White Satin ChromeChrome Dull Chrome Dull(1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise.(2) cULus Listed only.(3) 200°F (93°C) maximum.(4) cULus listed “corrosion resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request.(5) FM Approvals finish as “Polyester coated” applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white.(6) LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475.(7) cULus listed Corrosion Resistant Material DataFrame: DZR Brass, QM Brass, or Low Lead BrassDefl ector:CDA Alloy 220, 260, or 510Load Screw\Pintle: CDA Alloy 360 or 544Cup:CDA Alloy 651 or 693Washer:Nickel Alloy 440 or 360, coated with PTFE Adhesive TapeBulb:GlassOrdering Information Specify: 1. Sprinkler Model: [F1FR28][F1FR40][F1FR42][F1FR42LL][F1FRXLH][F1FR56][F1FR56LL]2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent][Upright][Conventional][Horizontal Sidewall][Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2]4. Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)]5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP]7. Escutcheon Finish (where applicable)8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment]9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers]10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Powered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf | 11 of 211TABLE OF CONTENTS 12. Reliable Automatic Sprinkler Co., Inc.(800) 431-1588 Sales Offices(800) 848-6051 Sales Fax(914) 829-2042 Corporate Officeswww.reliablesprinkler.com Internet AddressManufactured byRecycledPaper Revision lines indicate updated or new data.EG. Printed in U.S.A. 06 /15P/N 9999970300The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.• Automatic sprinklers• Flush automatic sprinklers• Recessed automatic sprinklers• Concealed automatic sprinklers• Adjustable automatic sprinklers• Dry automatic sprinklers• Intermediate level sprinklers• Open sprinklers• Spray nozzles• Alarm valves• Retarding chambers• Dry pipe valves• Accelerators for dry pipe valves• Mechanical sprinkler alarms• Electrical sprinkler alarm switches• Water flow detectors• Deluge valves• Detector check valves• Check valves• Electrical system• Sprinkler emergency cabinets• Sprinkler wrenches• Sprinkler escutcheons and guards• Inspectors test connections• Sight drains• Ball drips and drum drips• Control valve seals• Air maintenance devices• Air compressors• Pressure gauges• Identification signs• Fire department connectionReliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock.Reliable...For Complete ProtectionPowered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf | 12 of 211TABLE OF CONTENTS 13. 25-2011-PDFO1 - Operation and Maintenance ManualsPage 13 of 211TABLE OF CONTENTS O&M Manuals.pdf 175 % 001 von 211