     Operations and Maintenance Manuals2050 Versailles RdLexington, Kentucky
     40504
     
 2.  
     Insert your text hereTABLE OF CONTENTSO1 -Operation and Maintenance
     Manuals014 Model F1FR 56 Quick Response
     Sprinklers.......................................5-1225-2011-PDF..............................................................................................................14-143Flex
     Drop...................................................................................................................145-150test
     papers phase
     1............................................................................................152-155test
     papers phase
     2............................................................................................157-160O2
     -Operation and Maintenance Manuals08 11 00 Steel Doors and Frames
     O&M................................................162-16408 21 20 Flush
     Wood Veneer Doors O&M...........................................166-16608
     71 00 Door Hardware
     O&M..................................................................168-17010
     26 00 Wall Protection
     O&M....................................................................172-172MX-3051_20221201_123402........................................................................174-197MX-3051_20221201_125328........................................................................199-202MX-3051_20221201_125603........................................................................204-205O3
     -Operation and Maintenance Manuals
     
 3.  
     Insert your text hereWood Concept
     O&M..........................................................................................207-207O4
     -Operation and Maintenance ManualsO and
     M.....................................................................................................................209-211
     
 4.  
     014 Model F1FR 56 Quick Response SprinklersO1 - Operation and Maintenance
     ManualsPage 4 of 211TABLE OF CONTENTS
     
 5.  
     Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford,
     New York 10523Model F1FR SeriesQuick ResponseGlass Bulb SprinklersBulletin
     014 Rev. M Bulletin 014 Rev. M Model F1FR56 Sprinkler TypesStandard Spray
     UprightStandard Spray PendentConventional Upright/PendentVertical
     SidewallHorizontal SidewallModel F1FR56 Recessed Sprinkler TypesStandard
     Spray PendentHorizontal SidewallModel F1FR56 Concealed Sprinkler
     TypesStandard Spray PendentModel F1FR42, F1FRXLH & F1FR28 Sprinkler
     TypesStandard Spray UprightStandard Spray PendentModel F1FR40 Sprinkler
     TypesStandard Spray PendentModel F1FR42, F1FR40, F1FRXLH & F1FR28 Recessed
     Sprinkler TypesStandard Spray PendentModel F1FR56LL & F1FR42LL NSF Certifi
     ed Low Lead Sprinkler TypesStandard Spray Pendent with less than 0.25% Lead
     ContentListing & ApprovalsThe following organizations provide Listings or
     Approvals for various Model F1FR series sprinklers. See the Design and
     Installation table in this Bulletin for information on specific listings
     and approvals applicable to each sprin-kler.1. Underwriters Laboratories
     Inc. and Certified for Canada (cULus).2. FM Approvals (FM)3. Loss
     Prevention Certification Board (LPCB)4. Vertrauen durch Sicherheit (VdS)5.
     NSF Certified to NSF/ANSi Standard 61 Annex G (NSF)6. EC Certificate:
     0786-CPD-40239 (RA1414), 0786-CPD-40251 (RA1425), 0786-CPD-40252 (RA1475)
     (EC)UL Listing CategorySprinklers, Automatic & Open (VNIV)Quick Response
     SprinklerPendent ConventionalRecessedPendent/F1/F2UprightVertical Sidewall
     Horizontal SidewallRecessedHorizontal
     SidewallRecessedPendent/FPConcealedPendent XLH Upright XLH PendentXLH
     RecessedPendent F1/F2XLH RecessedPendent FPProduct DescriptionReliable
     Model F1FR series sprinklers are quick-response automatic sprin-klers with
     a glass bulb thermal element. Model F1FR series sprinklers are Stan-dard
     Spray sprinklers, with the excep-tion of the Model F1FR56 Conventional
     sprinkler which is an Old-style/Conven-tional sprinkler.The Model F1FR
     Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These
     sprinklers have demonstrat-ed response times in laboratory tests which are
     five to ten times faster than standard response sprinklers. This quick
     response enables the Model F1FR Series sprinklers to apply water to a fire
     faster than standard-response sprinklers of the same temperature rating.The
     glass bulb consists of an accurately controlled amount of special fluid
     hermetically sealed inside a precisely man-ufactured glass capsule. This
     glass bulb is specially con-structed to provide fast thermal
     response.Powered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014
     Model F1FR 56 Quick Response Sprinklers.pdf | 5 of 211TABLE OF CONTENTS
     
 6.  
     2.At normal temperatures, the glass bulb contains the fluid in both the
     liquid and vapor phases. The vapor phase can be seen as a small bubble. As
     heat is applied, the liquid expands, forcing the bubble smaller and smaller
     as the liq-uid pressure increases. Continued heating forces the liquid to
     push out against the bulb, causing the glass to shatter, opening the
     waterway and allowing the deflector to distrib-ute the discharging
     water.Model F1FR Series sprinklers provide a wide range of op-tions where
     quick-response, glass bulb sprinklers are used:• Pendent, recessed pendent,
     upright, horizontal side-wall, and vertical sidewall defl ectors• K-factors
     of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric)•
     Flush, recessed, and concealed installationsSee the Design and Installation
     Information table in this Bulletin for information on the approvals and
     availability of specific Model F1FR series sprinkler configurations.Model
     F1FR Recessed Pendent and Recessed Horizon-tal Sidewall sprinklers are
     required to be used with Reliable Model F1, F2, or FP recessed escutcheons.
     See the Re-cessed Escutcheon Data table in this Bulletin for listing and
     approval information with each specific Model F1FR series sprinkler. Model
     F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit
     assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment,
     respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a
     1/2-inch (12.7mm) threaded adjustment.Model F1FR56 Concealed Pendent and
     Model F1FR56LL Concealed Pendent sprinklers are required to be used with
     Model CCP cover plates. A standard profile Model CCP cov-er plate is
     available that provides up to 1/2-inch (12.7mm) of cover plate adjustment.
     In addition, a low profile Model CCP cover plate is also available that
     provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design
     and In-stallation Information and Listed and Approved Temperature Ratings
     tables in this Bulletin for further information on ap-proved cover plate
     options.ApplicationModel F1FR Series sprinklers are intended for use in
     accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the
     requirements of the Authority Hav-ing Jurisdiction. Care must be exercised
     that the k-factor, temperature rating, deflector style, and sprinkler type
     are in accordance with the requirements of the applicable design and
     installation standards. In addition, Model F1FR Series sprinklers must be
     used in accordance with their listings and approvals, as well as the
     information provided in this Bulletin.Installation Glass bulb sprinklers
     have orange bulb protectors or pro-tective caps to minimize bulb damage
     during shipping, han-dling and installation. Reliable sprinkler
     installation wrench-es are designed to install sprinklers with bulb
     protectors in place. Remove the bulb protector at the time when the
     sprin-kler system is placed in service for fire protection. Removal of the
     bulb protector before this time may leave the bulb vul-nerable to damage.
     Remove bulb protectors by undoing the clasp by hand. Do not use tools to
     remove bulb protectors.Model F1FR Series sprinklers must be installed with
     the Reliable sprinkler installation wrench identified in the Design and
     Installation Information table in this Bulletin. Any other wrench may
     damage the sprinkler. A leak tight sprinkler joint can be obtained with a
     torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the
     maximum recommended installation torque. Exceeding the maximum recommended
     installation torque may cause leakage or impairment of the
     sprinkler.Recessed SprinklersModel F1FR Series Recessed sprinklers are to
     be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the
     spe-cific model being installed. The Recessed Escutcheon Data table in the
     Bulletin identifies the only recessed escutcheons that are permitted to be
     used with each Model F1FR Series Recessed sprinkler. The use of any other
     recessed escutch-eon will void all approvals and negate all
     warranties.Concealed SprinklersModel F1FR Series Concealed Pendent
     sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable
     to the selected cover plate. Model F1FR56 Concealed Pendent and Model
     F1FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP
     cup. A protective cap is in-stalled at the factory that should remain on
     the sprinkler until the sprinkler is installed and should then be
     reinstalled on the sprinkler until the cover plate is installed. The
     concealed sprinkler assemblies are completed by the installation of a Model
     CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler
     cup assemblies are joined using a cover plate skirt with flexible tabs for
     threaded engage-ment. A choice of two Model CCP cover plate assemblies
     provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do
     not install Model F1FR Series Concealed Pendent sprinklers in ceilings
     which have positive pressure in the space above.Model F1FR Series Concealed
     Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in
     the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching
     surfaces and to install the sprinkler in the fitting. Remove the protective
     cap to install the sprinkler, then reinstall the protective cap until the
     cover plate is installed. When inserting or remov-ing the wrench from the
     sprinkler/cup assembly, care should be taken to prevent damage to the
     sprinkler. Do not wrench any other part of the sprinkler/cup assembly.
     Installation is com-pleted by removing the protective cap from the
     sprinkler and pushing the cover plate onto the cup. Final adjustment is
     made by hand turning the cover plate until the skirt flange makes full
     contact with the ceiling. Cover plate removal requires turning the cover
     plate in the counter clockwise direction. After installation, inspect all
     sprinklers to ensure that there is a gap between the cover plate and
     ceiling and that the four cup slots are open and free from any air flow
     impediment to the space above.Concealed cover plate/cup assemblies are
     listed only for use with specific sprinklers. The use of any concealed
     cover plate/cup assembly other than the Reliable Model CCP with Model
     F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers or
     the use of the Model CCP Concealed cover plate assembly on any sprinkler
     with which it is not specifically listed my prevent good fire protection
     and will void all guarantees, warranties, listings and approvals.Powered By
     Pype Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick
     Response Sprinklers.pdf | 6 of 211TABLE OF CONTENTS
     
 7.  
     3.Design and Installation InformationModelNominalK-factorNominalOrifi
     ceDiameterDefl ector/OrientationNominal Sprinkler HeightInstallation
     WrenchSINListingsandApprovalsApproval NotesUS Metric inches mm inches
     mmF1FR282.8 40 3/8 10Pendent 2.25 57 D RA1411 cULus 2Recessed Pendent 2.25
     57 GFR2 RA1411 cULus 2Upright 2.25 57 D RA1421 cULus 1,2F1FR404.0 57 3/8
     10Pendent 2.25 57 D RA1418 VdSRecessed Pendent 2.25 57 GFR2 RA1418
     VdSF1FR424.2 60 7/16 10Pendent 2.25 57 D RA1413 cULus 2Recessed Pendent
     2.25 57 GFR2 RA1413 cULus 2Upright 2.25 57 D RA1423 cULus 1,2F1FR42LL4.2 60
     7/16 10Pendent 2.25 57 D RA1410 cULus, NSFRecessed Pendent 2.25 57 GFR2
     RA1410 cULus, NSFF1FRXLH(F1FR42 with Pintle)4.2 60 7/16 10Pendent 2.25 57 D
     RA1413 cULus 2Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2Upright 2.25 57 D
     RA1423 cULus 1,2F1FR565.6 80 1/2 15Pendent 2.25 57 D RA1414cULus, FM, LPCB,
     VdS, EC1,2,3,4Recessed Pendent 2.25 57 GFR2 RA1414cULus, FM, LPCB, VdS,
     EC1,2,3,4Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6Upright 2.25
     57 D RA1425cULus, FM, LPCB, VdS, EC1,2,3,4"Conventional(Pendent or
     Upright)"2.25 57 D RA1475 LPCB, VdS, EC 4F1FR56LL5.6 80 1/2 15Pendent 2.25
     57 D RA1415 cULus, NSF 1Recessed Pendent 2.25 57 GFR2 RA1415 cULus,
     NSFConcealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6F1FR565.6 80 1/2
     15Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7Recessed Horizontal
     Sidewall2.63 67 GFR2 RA1435 cULus, FM 8F1FR565.6 80 1/2 15Vertical Sidewall
     (Pendent or Upright)2.25 57 D RA1485cULus, FM, LPCB1,2,3,9(1) cULus Listed
     Corrosion Resistant sprinkler when ordered with available Polyester
     coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with
     available Electroless Nickel PTFE plating.(3) Available with FM approved
     Polyester coating in black or white.(4) Available with LPCB and VdS
     approved Polyester coating.(5) VdS and EC approvals of the F1FR56 Concealed
     Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only.
     VdS approved sprin-klers must use Norbulb brand glass bulbs with the
     1/2-inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1FR56
     Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be
     used with Reliable Model CCP cover plates, available as either standard
     depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch
     (8.0 mm) of adjustment.(7) cULus Listing of the F1FR56 Horizontal Sidewall
     sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of
     the F1FR56 Hori-zontal Sidewall sprinkler is for Light Hazard occupancies
     only.(8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal
     Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1FR56
     Vertical Sidewall sprinkler is listed and approved for use only in Light
     Hazard occupancies. Minimum to maximum deflector to ceil-ing distance shall
     be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56
     Vertical Sidewall sprinkler is for installation in the Pendent position
     only.Technical Data:Sensitivity: Quick-responseThread Size: 1/2-inch NPT
     standard; ISO 7-R1/2 optionalMaximum Working Pressure: 175 psi (12 bar) -
     100% Factory tested hydrostatically to 500 psi (34.5 bar)Powered By Pype
     Inc.| O1 - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick
     Response Sprinklers.pdf | 7 of 211TABLE OF CONTENTS
     
 8.  
     4.Listed and Approved Temperature Ratings ModelDefl
     ector/OrientationOrdinary Temp.Classifi cation100°F (38°C) Max. Ambient
     Temp.Intermediate Temp.Classifi cation150°F (65°C) Max. Ambient Temp.High
     Temp.Classifi cation225°F (107°C) Max.Ambient Temp.135°F (57°C) Temp.
     Rating155°F (68°C) Temp. Rating175°F (79°C) Temp. Rating200°F (93°C) Temp.
     Rating286°F (141°C) Temp. RatingOrange Bulb Red Bulb Yellow Bulb Green Bulb
     Blue BulbF1FR28Pendent cULusRecessed Pendent cULus --Upright
     cULusF1FR40Pendent VdSRecessed Pendent VdS --F1FR42Pendent cULusRecessed
     Pendent cULus --Upright cULusF1FR42LLPendent -- cULus, NSF --Recessed
     Pendent -- cULus, NSF --F1FRXLHPendent cULusRecessed Pendent cULus
     --Upright cULusF1FR56Pendent cULus, FM, LPCB, VdS, ECRecessed Pendent
     cULus, FM, LPCB, VdS, EC --Concealed Pendent* cULus cULus,VdS,EC cULus
     --Upright cULus, FM, LPCB, VdS, EC“Conventional(Pendent or Upright)”LPCB,
     VdS, ECF1FR56LLPendent -- cULus, NSF --Recessed Pendent -- cULus, NSF
     --Concealed Pendent* -- cULus, NSF --F1FR56Horizontal Sidewall cULus,
     FMRecessed Horizontal SidewallcULus, FM --F1FR56Vertical Sidewall (Pen-dent
     or Upright)cULus, FM, LPCB* Model F1FR56 Concealed Pendent and F1FR56LL
     Concealed Pendent sprinklers must be used with Reliable Model CCP cover
     plates. For Ordinary Temperature Classification sprinklers use a 135°F
     (57°C) temperature rated cover plate. For Intermediate Temperature
     Classification sprinklers use a 165°F (74°C) temperature rated cover
     plate.Recessed Escutcheon Data ModelDefl ector/OrientationListed and
     Approved Recessed EscutcheonsSINModel F1(Fig. 1 & 3)3/4-inch (19mm)
     adjustmentModel F2(Fig. 1 & 3)1/2-inch (12.7mm) adjustmentModel FP(Fig.
     2)1/2-inch (12.7mm) adjustmentF1FR28Recessed Pendent cULus cULus cULus
     RA1411F1FR40Recessed Pendent VdS VdS VdS RA1418F1FR42Recessed Pendent cULus
     cULus cULus RA1413F1FR42LLRecessed Pendent cULus, NSF cULus, NSF cULus, NSF
     RA1410F1FR42XLHRecessed Pendent cULus cULus cULus RA1413F1FR56Recessed
     PendentcULus, LPCB, VdS, ECcULus, FM, LPCB, VdS, ECcULus, VdS, EC
     RA1414F1FR56LLRecessed Pendent cULus, NSF cULus, NSF cULus, NSF
     RA1415F1FR56Recessed Horizontal Sidewall cULus cULus, FM cULus
     RA1435Powered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014
     Model F1FR 56 Quick Response Sprinklers.pdf | 8 of 211TABLE OF CONTENTS
     
 9.  
     5.Fig. 1Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28
     Recessed Pendent sprinkler with Model F1 or F2 escutcheonFig. 2Model
     F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed
     Pendent sprinkler with Model FP escutcheonPowered By Pype Inc.| O1 -
     Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response
     Sprinklers.pdf | 9 of 211TABLE OF CONTENTS
     
 10. 
     6.Fig. 3Model F1FR56 Recessed Horizontal Sidewall sprinkler with Model F1
     or F2 escutcheonFig. 4Model F1FR56/F1FR56LL Concealed Pendent sprinkler
     with standard depth1/2-inch (12.7mm) adjustment - Model CCP cover
     platePowered By Pype Inc.| O1 - Operation and Maintenance Manuals | 014
     Model F1FR 56 Quick Response Sprinklers.pdf | 10 of 211TABLE OF CONTENTS
     
 11. 
     7.Fig. 5 - Model F1FR56/F1FR56LL Concealed Pendent sprinkler with low
     profile5/16-inch (8.0mm) adjustment - Model CCP cover plateMaintenance The
     Model F1FR Series sprinklers should be inspected and the sprinkler system
     maintained in accordance with NFPA 25. Do not clean sprinklers with soap
     and water, ammonia or any other cleaning fluids. Remove dust by using a
     soft brush or gentle vacuuming. Replace any sprinkler which has been
     painted (other than factory applied) or damaged in any way. A stock of
     spare sprinklers should be maintained to allow quick replacement of damaged
     or operated sprinklers. Finishes (1) Standard FinishesSprinkler Escutcheon
     Cover plate(1)Bronze Brass ChromeChrome Plated Chrome WhitePolyester
     PlatedCoated (4)(5)(6)White PaintedSpecial Application FinishesSprinkler
     Escutcheon Cover plate(1)Electroless Nickel PTFE(7)Electroless Nickel PTFE
     Bright BrassBright Brass(3)Bright Brass Black PlatingBlack Plated Black
     Plated Black PaintBlack Paint(2)(6)Black Paint Off WhiteOff White(2)(6) Off
     White Satin ChromeChrome Dull Chrome Dull(1) Other finishes and colors are
     available on special order. Consult the factory for details. Custom color
     painted sprinklers may not retain their UL Corrosion resistance listing.
     Coverplate custom paint is semi-gloss, unless specified otherwise.(2) cULus
     Listed only.(3) 200°F (93°C) maximum.(4) cULus listed “corrosion
     resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425
     (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or
     white. Corrosion resistance in other polyester colors is available upon
     request.(5) FM Approvals finish as “Polyester coated” applies to SIN Number
     RA1414, RA1435 and RA1425 in standard black or white.(6) LPCB and VdS
     Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475.(7)
     cULus listed Corrosion Resistant Material DataFrame: DZR Brass, QM Brass,
     or Low Lead BrassDefl ector:CDA Alloy 220, 260, or 510Load Screw\Pintle:
     CDA Alloy 360 or 544Cup:CDA Alloy 651 or 693Washer:Nickel Alloy 440 or 360,
     coated with PTFE Adhesive TapeBulb:GlassOrdering Information Specify: 1.
     Sprinkler Model:
     [F1FR28][F1FR40][F1FR42][F1FR42LL][F1FRXLH][F1FR56][F1FR56LL]2. Sprinkler
     Deflector/Orientation: [Pendent][Recessed
     Pendent][Upright][Conventional][Horizontal Sidewall][Recessed Horizontal
     Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO
     7-R1/2]4. Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F
     (79°C)][200°F (93°C)][286°F (141°C)]5. Sprinkler Finish 6. Escutcheon
     Model: [F1][F2][FP]7. Escutcheon Finish (where applicable)8. Cover plate
     Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP
     5/16-inch (8.0mm) adjustment]9. Cover plate Temperature Rating: [135°F
     (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use
     with Intermediate Temperature sprinklers]10. Cover plate Finish Note: When
     Model F1FR Series Recessed sprinklers are ordered, the sprinklers and
     escutcheons are packaged separately. Powered By Pype Inc.| O1 - Operation
     and Maintenance Manuals | 014 Model F1FR 56 Quick Response Sprinklers.pdf |
     11 of 211TABLE OF CONTENTS
     
 12. 
     Reliable Automatic Sprinkler Co., Inc.(800) 431-1588 Sales Offices(800)
     848-6051 Sales Fax(914) 829-2042 Corporate Officeswww.reliablesprinkler.com
     Internet AddressManufactured byRecycledPaper Revision lines indicate
     updated or new data.EG. Printed in U.S.A. 06 /15P/N 9999970300The equipment
     presented in this bulletin is to be installed in accordance with the latest
     published Standards of the National Fire Protection Association, Factory
     Mutual Research Corporation, or other similar organizations and also with
     the provisions of governmental codes or ordinances whenever
     applicable.Products manufactured and distributed by Reliable have been
     protecting life and property for over 90 years, and are installed and
     serviced by the most highly qualified and reputable sprinkler contractors
     located throughout the United States, Canada and foreign countries.•
     Automatic sprinklers• Flush automatic sprinklers• Recessed automatic
     sprinklers• Concealed automatic sprinklers• Adjustable automatic
     sprinklers• Dry automatic sprinklers• Intermediate level sprinklers• Open
     sprinklers• Spray nozzles• Alarm valves• Retarding chambers• Dry pipe
     valves• Accelerators for dry pipe valves• Mechanical sprinkler alarms•
     Electrical sprinkler alarm switches• Water flow detectors• Deluge valves•
     Detector check valves• Check valves• Electrical system• Sprinkler emergency
     cabinets• Sprinkler wrenches• Sprinkler escutcheons and guards• Inspectors
     test connections• Sight drains• Ball drips and drum drips• Control valve
     seals• Air maintenance devices• Air compressors• Pressure gauges•
     Identification signs• Fire department connectionReliable offers a wide
     selection of sprinkler components. Following are some of the many
     precision-made Reliable products that guard life and property from fire
     around the clock.Reliable...For Complete ProtectionPowered By Pype Inc.| O1
     - Operation and Maintenance Manuals | 014 Model F1FR 56 Quick Response
     Sprinklers.pdf | 12 of 211TABLE OF CONTENTS
     
 13. 
     25-2011-PDFO1 - Operation and Maintenance ManualsPage 13 of 211TABLE OF
     CONTENTS
     

O&M Manuals.pdf
175 %
001 von 211