www.measure-tech.com
Open in
urlscan Pro
66.96.130.113
Public Scan
URL:
https://www.measure-tech.com/microwave.html
Submission: On November 30 via manual from US — Scanned from CH
Submission: On November 30 via manual from US — Scanned from CH
Form analysis
1 forms found in the DOMPOST php/rfq.php
<form id="contactFormPop" method="post" action="php/rfq.php">
<div class="form-group">
<label for="pn">Part Number</label>
<input class="form-control" id="pn" name="pn" required="required" placeholder="Part Number*" data-validation-required-message="Please enter part number.">
<p class="help-block text-danger"></p>
</div>
<div class="form-group">
<label for="qty">Quantity</label>
<input class="form-control" id="qty" name="qty" required="required" placeholder="1*" data-validation-required-message="Please enter quantity.">
<p class="help-block text-danger"></p>
</div>
<div class="form-group">
<label for="qty">Name</label>
<input class="form-control" id="Name" name="name" required="required" placeholder="Your Name*" data-validation-required-message="Please enter your name.">
<p class="help-block text-danger"></p>
</div>
<div class="form-group">
<label for="qty">Company Name</label>
<input class="form-control" id="cName" name="cName" placeholder="Company Name*" data-validation-required-message="Please enter company name.">
<p class="help-block text-danger"></p>
</div>
<div class="form-group">
<label for="email">Phone Number</label>
<input class="form-control" id="phone" name="phone" placeholder="Your Phone Number*" data-validation-required-message="Please enter your phone number.">
<p class="help-block text-danger"></p>
</div>
<div class="form-group">
<label for="email">Email</label>
<input class="form-control" type="email" id="email" name="email" placeholder="Your Email*" required="required" data-validation-required-message="Please enter your email address.">
<p class="help-block text-danger"></p>
</div>
<div class="form-group stcaptcha">
<div class="g-recaptcha" data-sitekey="6Lcbjw0bAAAAAOPdP33o0urrX1V7jYvZyhIQllEQ">
<div style="width: 304px; height: 78px;">
<div><iframe title="reCAPTCHA" width="304" height="78" role="presentation" name="a-f97bhij13q88" frameborder="0" scrolling="no"
sandbox="allow-forms allow-popups allow-same-origin allow-scripts allow-top-navigation allow-modals allow-popups-to-escape-sandbox allow-storage-access-by-user-activation"
src="https://www.google.com/recaptcha/api2/anchor?ar=1&k=6Lcbjw0bAAAAAOPdP33o0urrX1V7jYvZyhIQllEQ&co=aHR0cHM6Ly93d3cubWVhc3VyZS10ZWNoLmNvbTo0NDM.&hl=de-CH&v=-QbJqHfGOUB8nuVRLvzFLVed&size=normal&cb=4en2rj3k4xpv"></iframe>
</div><textarea id="g-recaptcha-response" name="g-recaptcha-response" class="g-recaptcha-response" required="required"
style="width: 250px; height: 40px; border: 1px solid rgb(193, 193, 193); margin: 10px 25px; padding: 0px; resize: none; display: none;"></textarea>
</div><iframe style="display: none;"></iframe>
</div>
</div>
<div class="text-center">
<button class="btn btn-block btn-round btn-d" id="cfsubmitv" type="submit">Submit</button>
</div>
<div class="stThanks alert alert-success alert-dismissible">RFQ submitted successfully</div>
</form>
Text Content
Loading... Innovate and Improve Toggle navigation * Home * Products * Temperature Sensors * Level Sensors * Temperature & Pressure Switches * Communication & Control Products * SiO2 CABLES * Custom High Temperature RF Solutions * Metrology * Thermal Voltage Converter * High Voltage Thermal Voltage Converter * Vacuum Thermocouples * AC/DC Current Shunts * Applications * Repairs * About Us * Company Profile * Certificates * AS9100D/ISO9001:2015 * EASA REPAIR STATION * FAA FIS LETTER * FAA REPAIR STATION * Terms & conditions * Contact Us * INSTANT RFQ * General Inquiry SILICON DIOXIDE (SIO2) CABLES FEATURES * Silicone Dioxide Dielectric * 50 ohm nominal impedance * Hermetically sealed cable assembly * Cable can withstand temperatures exceed 900°C * Connectors can be made to withstand temperature exposures in excess of 600°C * Excellent Phase stability over temperature (does not exhibit PTFE “knee”) * Semi-rigid (can be hand formed) * Can be bent per customer’s requirements * Cables can be phase matched Measure Tech’s SiO2 cable assemblies are the ideal choice for applications requiring phase stability and high performance in extreme operating environments. MEASURE TECH ADVANTAGE The Measure Tech SiO2 cables and hermetically sealed connectors are designed and manufactured in house with very little outsourcing. As a result, Measure Tech can offer lead times that cannot be matched and some cable configurations that can be produced rapidly. In addition, our qualified engineering team is available to help solve your program’s challenges. CABLE DESIGN For over 20 years Measure Tech has provided SiO2 semi ridged microwave cable assemblies for use in high temperature applications where no other microwave cable would not survive. Formulating the high purity (99.98+%) fumed silicon dioxide dielectric years of research and experimentation. The result is a process where α-quartz is converted to β-quartz which provides a lower density and dielectric constant to Teflon wrapped PTFE coaxial microwave cables. The advantage SiO2 cable has over standard cable is a temperature rating from -270°C to 1,000°C while maintaining the most exceptional properties of low loss and phase stability. Current cable offers include diameters of 0.090”, 0.125”, 0.142”, 0.200", and 0.275” with customer configurations available. CONNECTOR DESIGN Hermetically sealed connectors are designed and manufactured at Measure Tech using specially formulated crack free glass. Polycrystalline glass ceramic, developed by Measure Tech combined with super alloys allow the connectors the ability to operate to 600°C and above. 100% of connectors are Helium leak tested to 1x10^8cc/sec prior to cable assembly. Connectors are manufactured per military specifications such as SMA, N, and TNC. Custom connectors can be designed to meet customer’s requirements. CABLE AND CONNECTOR INTEGRATION Cables are cut to length in accordance with customer requirements. Both ends are prepped and the cables are pressurized (backfilled) with 100% Helium prior to the installation of connectors. The assembly is electrically tested for electrical performance and then welding is performed in house using automated welding machines to ensure repeatability. All welds are qualified which includes cross-sectioning samples and measuring weld penetration. Each cable when complete is tested to assure the final product leak rate does not exceed 1x10^8cc/sec of Helium. As a final inspection process, electrical testing is performed on 100% of cable assemblies and data is provided to the customer. SPECIFICATIONS The following specifications are applicable for Measure Tech’s SiO2 cables. Contact us for more information. Parameter Cable Diameter (in.) 0.090 0.141 0.200 0.275 Cut-off Frequency (GHz) 65 38 25 18 Weight (lbs./ft.) 0.016 0.032 0.046 0.084 Minimum Bend Radius* 0.3 0.45 0.7 0.70 Characteristic Impedance (Ohms) 50 Capacitance (farad/ft.) 25 Velocity of Propagation 80% SWR 2 – 4 GHz: 1.25:1 2 – 8 GHz: 1.25:1 8– 12 GHz: 1.30:1 12– 16 GHz: 1.35:1 16– 18 GHz: 1.50:1 *Smaller factory bend radii available with custom tooling INSERTION LOSS Insertion Loss (dB/ft.) - Cable Insertion Loss (dB/pair) - Connector Frequency (GHz) Cable Diameter (in.) Frequency (GHz) Insertion Loss 0.09 0.141 0.125 0.200 0.275 0.3 0.098 0.055 0.065 0.038 0.029 0.5 0.05 0.9 0.175 0.105 0.112 0.068 0.045 2 0.3 2 0.265 0.153 0.175 0.107 0.070 4 0.325 4 0.391 0.232 0.24 0.163 0.119 8 0.375 8 0.585 0.355 0.395 0.25 0.170 12 0.425 12 0.745 0.46 0.525 0.33 0.238 16 0.475 18 0.953 0.603 0.665 0.438 0.308 18 0.5 24 1.145 0.73 0.815 0.54 -- 40 1.595 1.004 1.13 -- -- To calculate the cable assembly lose multiply length in feet by loss in db/ft and add the applicable loss for connector pair. SiO2 cable assemblies are designed for demanding applications which minimal phase change over temperature is required. The Measure Tech SiO2 cables have completely has eliminated the PTFE Knee which resulted in a close to linear curve with phase variation of close to 70% less than conventional PTFE microwave cable assemblies. Measure Tech has the ability to phase match cable assemblies per customer requirements. © 2018 Measure tech inc. 20650 Bahama Street Chatsworth CA, 91311 •Phone: (818) 734-9075 •Fax: (818) 734-9087 contact us × INSTANT RFQ Part Number Quantity Name Company Name Phone Number Email Submit RFQ submitted successfully Close