blog.xtralight.com Open in urlscan Pro
2606:2c40::c73c:67e2  Public Scan

Submitted URL: http://ow.ly/9s2650HzWBJ
Effective URL: https://blog.xtralight.com/uv-dosage-for-disinfection
Submission: On January 21 via manual from US — Scanned from DE

Form analysis 2 forms found in the DOM

POST https://forms.hsforms.com/submissions/v3/public/submit/formsnext/multipart/2323907/65ee8857-134b-46d2-b5b4-810119170c00

<form novalidate="" accept-charset="UTF-8" action="https://forms.hsforms.com/submissions/v3/public/submit/formsnext/multipart/2323907/65ee8857-134b-46d2-b5b4-810119170c00" enctype="multipart/form-data"
  id="hsForm_65ee8857-134b-46d2-b5b4-810119170c00_3075" method="POST"
  class="hs-form stacked hs-custom-form hs-form-private hsForm_65ee8857-134b-46d2-b5b4-810119170c00 hs-form-65ee8857-134b-46d2-b5b4-810119170c00 hs-form-65ee8857-134b-46d2-b5b4-810119170c00_88cc3001-cfce-4283-944c-6aa7f8ad6673"
  data-form-id="65ee8857-134b-46d2-b5b4-810119170c00" data-portal-id="2323907" target="target_iframe_65ee8857-134b-46d2-b5b4-810119170c00_3075" data-reactid=".hbspt-forms-0" data-hs-cf-bound="true">
  <div class="hs_email hs-email hs-fieldtype-text field hs-form-field" data-reactid=".hbspt-forms-0.1:$0"><label id="label-email-65ee8857-134b-46d2-b5b4-810119170c00_3075" class="" placeholder="Enter your "
      for="email-65ee8857-134b-46d2-b5b4-810119170c00_3075" data-reactid=".hbspt-forms-0.1:$0.0"><span data-reactid=".hbspt-forms-0.1:$0.0.0"></span></label>
    <legend class="hs-field-desc" style="display:none;" data-reactid=".hbspt-forms-0.1:$0.1"></legend>
    <div class="input" data-reactid=".hbspt-forms-0.1:$0.$email"><input id="email-65ee8857-134b-46d2-b5b4-810119170c00_3075" class="hs-input" type="email" name="email" required="" placeholder="" value="" autocomplete="email"
        data-reactid=".hbspt-forms-0.1:$0.$email.0" inputmode="email"></div>
  </div>
  <div class="hs_blog_xtralight_blog_subscription hs-blog_xtralight_blog_subscription hs-fieldtype-radio field hs-form-field active" style="display:none;" data-reactid=".hbspt-forms-0.1:$1"><label
      id="label-blog_xtralight_blog_subscription-65ee8857-134b-46d2-b5b4-810119170c00_3075" class="" placeholder="Enter your Notification Frequency" for="blog_xtralight_blog_subscription-65ee8857-134b-46d2-b5b4-810119170c00_3075"
      data-reactid=".hbspt-forms-0.1:$1.0"><span data-reactid=".hbspt-forms-0.1:$1.0.0">Notification Frequency</span></label>
    <legend class="hs-field-desc" style="display:none;" data-reactid=".hbspt-forms-0.1:$1.1"></legend>
    <div class="input" data-reactid=".hbspt-forms-0.1:$1.$blog_xtralight_blog_subscription"><input name="blog_xtralight_blog_subscription" class="hs-input" type="hidden" value="instant"
        data-reactid=".hbspt-forms-0.1:$1.$blog_xtralight_blog_subscription.0" placeholder="Notification Frequency"></div>
  </div>
  <div class="hs_lifecyclestage hs-lifecyclestage hs-fieldtype-radio field hs-form-field active" style="display:none;" data-reactid=".hbspt-forms-0.1:$2"><label id="label-lifecyclestage-65ee8857-134b-46d2-b5b4-810119170c00_3075" class=""
      placeholder="Enter your Lifecycle Stage" for="lifecyclestage-65ee8857-134b-46d2-b5b4-810119170c00_3075" data-reactid=".hbspt-forms-0.1:$2.0"><span data-reactid=".hbspt-forms-0.1:$2.0.0">Lifecycle Stage</span></label>
    <legend class="hs-field-desc" style="display:none;" data-reactid=".hbspt-forms-0.1:$2.1"></legend>
    <div class="input" data-reactid=".hbspt-forms-0.1:$2.$lifecyclestage"><input name="lifecyclestage" class="hs-input" type="hidden" value="subscriber" data-reactid=".hbspt-forms-0.1:$2.$lifecyclestage.0" placeholder="Lifecycle Stage"></div>
  </div><noscript data-reactid=".hbspt-forms-0.2"></noscript>
  <div class="hs_submit hs-submit" data-reactid=".hbspt-forms-0.5">
    <div class="hs-field-desc" style="display:none;" data-reactid=".hbspt-forms-0.5.0"></div>
    <div class="actions" data-reactid=".hbspt-forms-0.5.1"><input type="submit" value="Subscribe" class="hs-button primary large" data-reactid=".hbspt-forms-0.5.1.0"></div>
  </div><noscript data-reactid=".hbspt-forms-0.6"></noscript><input name="hs_context" type="hidden"
    value="{&quot;rumScriptExecuteTime&quot;:4009.1000003814697,&quot;rumServiceResponseTime&quot;:4305.89999961853,&quot;rumFormRenderTime&quot;:2.1999988555908203,&quot;rumTotalRenderTime&quot;:4309.199998855591,&quot;rumTotalRequestTime&quot;:295.70000076293945,&quot;embedAtTimestamp&quot;:&quot;1642787616012&quot;,&quot;formDefinitionUpdatedAt&quot;:&quot;1496773936735&quot;,&quot;pageUrl&quot;:&quot;https://blog.xtralight.com/uv-dosage-for-disinfection&quot;,&quot;pageTitle&quot;:&quot;UVC Dosage for Disinfection: Six Steps&quot;,&quot;source&quot;:&quot;FormsNext-static-5.432&quot;,&quot;sourceName&quot;:&quot;FormsNext&quot;,&quot;sourceVersion&quot;:&quot;5.432&quot;,&quot;sourceVersionMajor&quot;:&quot;5&quot;,&quot;sourceVersionMinor&quot;:&quot;432&quot;,&quot;timestamp&quot;:1642787616014,&quot;userAgent&quot;:&quot;Mozilla/5.0 (Windows NT 10.0; Win64; x64) AppleWebKit/537.36 (KHTML, like Gecko) Chrome/97.0.4692.71 Safari/537.36&quot;,&quot;originalEmbedContext&quot;:{&quot;portalId&quot;:&quot;2323907&quot;,&quot;formId&quot;:&quot;65ee8857-134b-46d2-b5b4-810119170c00&quot;,&quot;formInstanceId&quot;:&quot;3075&quot;,&quot;pageId&quot;:&quot;28799570918&quot;,&quot;region&quot;:&quot;na1&quot;,&quot;pageName&quot;:&quot;UVC Dosage for Disinfection: Six Steps&quot;,&quot;redirectUrl&quot;:&quot;https://www.xtralight.com/blog-notifications-thank-you/&quot;,&quot;target&quot;:&quot;#hs_form_target_form_33426646&quot;,&quot;contentType&quot;:&quot;blog-post&quot;,&quot;formsBaseUrl&quot;:&quot;/_hcms/forms/&quot;,&quot;formData&quot;:{&quot;cssClass&quot;:&quot;hs-form stacked hs-custom-form&quot;}},&quot;canonicalUrl&quot;:&quot;https://blog.xtralight.com/uv-dosage-for-disinfection&quot;,&quot;pageId&quot;:&quot;28799570918&quot;,&quot;pageName&quot;:&quot;UVC Dosage for Disinfection: Six Steps&quot;,&quot;redirectUrl&quot;:&quot;https://www.xtralight.com/blog-notifications-thank-you/&quot;,&quot;formInstanceId&quot;:&quot;3075&quot;,&quot;renderedFieldsIds&quot;:[&quot;email&quot;],&quot;formTarget&quot;:&quot;#hs_form_target_form_33426646&quot;,&quot;correlationId&quot;:&quot;09822a52-35d7-49c6-975f-ec483bce3899&quot;,&quot;contentType&quot;:&quot;blog-post&quot;,&quot;hutk&quot;:&quot;72cfafba7f26ce21420a615c7f0db6a1&quot;,&quot;captchaStatus&quot;:&quot;NOT_APPLICABLE&quot;,&quot;isHostedOnHubspot&quot;:true}"
    data-reactid=".hbspt-forms-0.7"><iframe name="target_iframe_65ee8857-134b-46d2-b5b4-810119170c00_3075" style="display:none;" data-reactid=".hbspt-forms-0.8"></iframe>
</form>

/hs-search-results

<form action="/hs-search-results" data-hs-cf-bound="true">
  <input type="text" class="hs-search-field__input" name="term" autocomplete="off" aria-label="Search" placeholder="Search">
  <input type="hidden" name="type" value="SITE_PAGE">
  <input type="hidden" name="type" value="BLOG_POST">
  <input type="hidden" name="type" value="LISTING_PAGE">
</form>

Text Content

We use cookies to provide you with a great user experience. By using XtraLight,
you accept our use of cookies.

Accept

 

 * Products
 * What's New
 * Rep Locator
 * Markets
 * Blog
 * Resources
 * Company

CHAT
+1 (800) 678 6960
Get Pricing

InSight

An XtraLight Blog

Notification Frequency

Lifecycle Stage




 * Recent Posts
 * News
 * Industry
 * Specs
 * Products
 * Awards


UV DOSAGE FOR DISINFECTION

By Cameron Dillehay
May 6, 2020 8:22:19 AM

Education Products Industry Ultraviolet



Viruses, bacteria, mold, and other pathogens are now stopped dead in their
tracks with XtraLight's UVC High Power Ultraviolet Disinfection System. Follow
these steps when using this effective and powerful light which emits 254 nm
wavelengths. The results will amaze you and give you peace of mind. 

 

UVC STEPS TO DISINFECTION:

STEPS:

 1. FOLLOW SAFETY GUIDELINES
 2. UNDERSTAND BASIC UVC TERMS
 3. IDENTIFY UV DOSE
 4. SURVEY AREA TO BE DISINFECTED
 5. CALCULATE ESTIMATED UV EXPOSURE TIME FOR DISINFECTING
 6. DISINFECT AREA AND VALIDATE WITH DOSIMETER CARDS

All surfaces within a certain distance will observe an assured level of
disinfection in a certain amount of time as long as the wavelengths are not
blocked from accessing the surface.

 

--------------------------------------------------------------------------------

 

STEP 1

FOLLOW SAFETY GUIDELINES

 

Do's

Don’t 's

 * Protect your eyes
 * Use protective PPE gear
 * Establish a plan to disinfect area 
 * Use safety timers
 * Train personnel in using UVC disinfecting system
 * Use hazard warning signs when in use
 * Keep fixture in protective case

 * Don’t expose eyes & skin to UVC
 * Don’t allow anyone to operate UVC fixture without reading safety instructions
 * Don’t allow anyone into area being treated with UVC
 * Don't touch the UVC lamps while operating



 * Excessive exposure to UVC can cause adverse effects on the eyes, retina,
   skin, circadian system, and immune system.
 * Human over exposure causes temporary skin redness and harsh eye irritation.
 * Symptoms may take 4 to 24 hours to occur after exposure.

 

STEP 2

UNDERSTANDING BASIC UVC TERMS      

RADIANT EXPOSURE = J/m2 or mJ/cm2

 * UV INTENSITY (I) = energy per unit surface area
 * EXPOSURE TIME (T) = exposure time in seconds
 * UV DOSE (FLUENCE) =  Intensity (I) x Time (T) expressed as mJ/cm2

LOG REDUCTION =  percentage of microorganisms inactivated 

 * EXAMPLE:
   a 1 log reduction will reduce the pathogen by 90%, before the UVC
   disinfection
   a 2 log reduction will reduce the pathogen by 99%, etc… 

--------------------------------------------------------------------------------

 

STEP 3

IDENTIFY UV DOSE

 * IDENTIFY TARGETED MICROORGANISMS
 * PAIR WITH LOG REDUCTION.   
   
   PATHOGENS
   
   Common Name
   
   Scientific Name
   
   3 Log Reduction
   
   Viruses
   
   Rota
   
   Rotaviruses (Human)
   
   32 mJ/cm2 
   
   Infectious Hepatitis
   
   Hepatitis B
   
   25 mJ/cm2 
   
   Adenovirus
   
    
   
   126 mJ/cm2 
   
   ECHO Virus
   
   Echovirus
   
   25 mJ/cm2 
   
   Bacteria
   
   Salmonella
   
   Salmonella Typhimurium
   
   22 mJ/cm2 
   
   Staph
   
   Staphylococcus aureus
   
   3.2 mJ/cm2 
   
   (2 log)
   
   Strep
   
   Streptococcus faecalis
   
   9.8 mJ/cm2 

 * UV dose determines what proportion of a specific microorganism is destroyed
   after a particular dose of UV radiation
   
   Target 50 mJ/cm2 to deactivate the average bacteria/virus
   
   Example from Log Reduction

Example from Log Reduction                 


DOWNLOAD
UV DOSE LOG REDUCTION GUIDE

--------------------------------------------------------------------------------

 

STEP 4

SURVEY AREA TO BE DISINFECTED

 * MEASURE DIMENSIONS OF AREA TO BE DISINFECTED USING MOBILE UNIT
 * TARGET UV DOSE is 50 mJ/cm2 
 * PLACE DOSIMETER CARDS ON TARGETED AREAS FOR VALIDATION OF UV DOSE

Our testing Data:

 

XLM

Product

UV Intensity

Exposure Time

Radiance Exposure

Distance

Handheld

2.8 mJ/cm2

17 sec

50mJ/cm2

4 in.

Mobile

.34 mJ/cm2

6 min

50mJ/cm2

5 ft

Mobile

.08  mJ/cm2

17 min

50mJ/cm2

10 ft

Mobile

.03 mJ/cm2

28 min

50mJ/cm2

15 ft

 



 

STEP 5

CALCULATE ESTIMATED EXPOSURE TIME FOR DISINFECTING

 * DETERMINE PLACEMENT OF MOBILE UNIT AND NUMBER OF UNITS TO DISINFECT AREA
 * CALCULATE EXPOSURE TIME = UV INTENSITY (at a specified distance) / UV DOSE /
   60 SECONDS
 * UV DOSE = 50 mJ/cm2 
   
   

--------------------------------------------------------------------------------

 

STEP 6

DISINFECT AREA AND VALIDATE WITH DOSIMETER CARDS

 * Color changes from yellow to orange validates 50 mJ/cm2 delivered
 * Color changes for orange to pink validates 100 mJ/cm2 delivered
   

 * Exit the room and run disinfection cycle

 * Verify exposure of card and make notations on the card to document the color
   change

 * Make exposure reading within 24 hours after disinfection 

 * Retain or discard the card in accord with site requirements

 * 1 time use of dosimeter cards

 Order UVC Products Here

To learn more about UV disinfection click here

 





 * 
 * 
 * 
 * 


CAMERON DILLEHAY


Cameron is a marketing specialist at XtraLight LED Solutions. He is affluent in
UI/UX website design, Graphic Illustration, 3D Rendering/Animation, SEO
optimization, Videography, and enjoys enlightening customers with innovative LED
technology. "The best marketing doesn't feel like marketing." - Tom Fishburne
Return Next
 * +1 (888) 204 8322
 * info@xtralight.com
 * 8812 Frey Road, Houston, Texas USA

 * 
 * 
 * 
 * 
 * 
   

 * LED Lighting Products
 * Rep Locator
 * Company
 * Markets
 * Contact
 * Blog
 * News
 * Careers
 * Intranet



--------------------------------------------------------------------------------

XTRALIGHT © 2022